Feedthrough
Isolator
Viewport
Vacuum Component
Vacuum Valve
Motion Feedthroughs
Others
| type | D-Sub |
|---|---|
| Insulation resistance value | 10⁹ ohm |
| Connection type | D-Sub(MIL-C-24308) |
| electrode | Kovar ® |
| Flange material | SUS 304 |
| sleeve | SUS 329 |
| Insulator | Borosilicate glass |
| Maximum temperature | 300℃ |
| The lowest temperature | -196℃ |
| Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
| Electric current / 1 pc. | 3 A |
| Total current/1 terminal | 30A |
| Withstand voltage: DC | 300 V |
| RoHS2 corresponding | ○ |
| type | D-Sub |
|---|---|
| Insulation resistance value | 10⁹ ohm |
| Connection type | D-Sub(MIL-C-24308) |
| electrode | Kovar ® |
| Flange material | SUS 304 |
| sleeve | SUS 304 |
| Insulator | Alumina ceramic |
| Maximum temperature | 450℃ |
| The lowest temperature | -196℃ |
| Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
| Electric current / 1 pc. | 3 A |
| Withstand voltage: DC | 300 V |
| RoHS2 corresponding | ○ |
| type | D-Sub |
|---|---|
| Insulation resistance value | 10⁹ ohm |
| Connection type | D-Sub(MIL-C-24308) |
| electrode | Kovar ® |
| Flange material | SUS 304 |
| sleeve | SUS 304 |
| Insulator | Alumina ceramic |
| Maximum temperature | 450℃ |
| The lowest temperature | -196℃ |
| Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
| Electric current / 1 pc. | 3 A |
| Withstand voltage: DC | 300 V |
| RoHS2 corresponding | ○ |
| type | D-Sub |
|---|---|
| Connection type | D-Sub(MIL-C-24308) |
| electrode | Kovar ® |
| Flange material | SUS 304 |
| Insulator | Glass |
| Maximum temperature | 200℃ |
| Leak rate | <1.0x10<sup>-8</sup>Pa・㎥/sec |
| Electric current / 1 pc. | 5 A |
| Withstand voltage: DC | 500 V |
| Material | oxygen-free copper |
|---|---|
| Maximum temperature | 400℃ |
| RoHS2 corresponding | ○ |
| RoHS2 corresponding | ○ |
|---|---|
| Vacuum and Air | For vacuum |
| Insulator | PEEK® |
|---|---|
| Maximum temperature | 250℃ |
| The lowest temperature | -50℃ |
| RoHS2 corresponding | ○ |
| Vacuum and Air | For vacuum |
| Withstand voltage: DC | 2 kV |
|---|---|
| Electric current / 1 pc. | 11 A |
| AWG # | 20 |
| contact | Copper alloy + gold-plated |
| Cable sheathing | Kapton ® |
| conductor | Ag-plated copper wire |
| Insulator | PEEK® |
| Maximum temperature | 250℃ |
| The lowest temperature | -50℃ |
| Vacuum and Air | For vacuum |
| RoHS2 corresponding | ○ |
| contact | Copper Alloy + Silver Plating |
|---|---|
| shell | Aluminum alloy |
| Bush | Synthetic rubber |
| Insulator | Synthetic resins |
| Maximum temperature | 125℃ |
| The lowest temperature | -55℃ |
| Vacuum and Air | For the atmosphere |
| RoHS2 corresponding | ○ |
| Withstand voltage: DC | 2.8 kV (reference) |
|---|---|
| Fixed voltage/temp | 150 V / 125 ℃ |
| Withstand voltage (AC) | 2000 V |
| Electric current / 1 pc. | 12A |
| AWG # | 20 |
| contact | Copper Alloy + Silver Plating |
| Cable sheathing | polyethylene |
| conductor | Soft copper wire |
| shell | Aluminum alloy |
| Bush | Synthetic rubber |
| Insulator | Synthetic resins |
| Maximum temperature | 125℃ |
| The lowest temperature | -20℃ |
| Vacuum and Air | For the atmosphere |
| RoHS2 corresponding | ○ |
| contact | Copper Alloy + Silver Plating |
|---|---|
| shell | Aluminum Alloy + Zinc Plating |
| Insulator | Synthetic resins |
| Maximum temperature | 125℃ |
| The lowest temperature | -55℃ |
| RoHS2 corresponding | ○ |
| Vacuum and Air | For the atmosphere |
| type | Micro D-Sub (MIL-DTL-83513) |
|---|---|
| Electric current / 1 pc. | 3 A |
| Withstand voltage: DC | 300 V |
| Connection type | Micro D-Sub (MIL-DTL-83513) |
| electrode | beryllium copper |
| Flange material | SUS 304L |
| Insulator | ceramic |
| Maximum temperature | 450℃ |
| The lowest temperature | -269℃ |
| Leak rate | <1x10<sup>-8</sup>Pa・㎥/sec |
| type | Low voltage and medium current |
|---|---|
| electrode | molybdenum (Mo) |
| Flange material | SUS 304 |
| Maximum temperature | 450℃ |
| The lowest temperature | -100℃ |
| Leak rate | <1x10<sup>-8</sup>Pa・㎥/sec |
| Withstand voltage: DC | 700 V |
| Electric current / 1 pc. | 28 A |
| Connection type | MS |
| type | BNC |
|---|---|
| Connection type | The atmosphere-side plug-fitti |
| electrode | Kovar ® |
| Flange material | SUS 304 |
| sleeve | Kovar ® |
| Insulator | Alumina ceramic |
| Maximum temperature | 450℃ |
| The lowest temperature | -196℃ |
| Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
| Classification | Flanged terminal |
| type | Ground shield |
| Impedance | 50 Ω |
| Insulation resistance value | 10⁹ ohm |
| frequency | 100 MHz |
| Withstand voltage: DC | 1 kV |
| Electric current / 1 pc. | 3 A |
| RoHS2 corresponding | ○ |
| type | BNC |
|---|---|
| Connection type | The atmosphere-side plug-fitti |
| electrode | Kovar ® |
| Flange material | SUS 304 |
| sleeve | Kovar ® |
| Insulator | Alumina ceramic |
| Maximum temperature | 450℃ |
| The lowest temperature | -196℃ |
| Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
| Classification | Flanged terminal |
| type | Ground shield |
| Impedance | 50 Ω |
| frequency | 100 MHz |
| Insulation resistance value | 10⁹ ohm |
| Withstand voltage: DC | 1 kV |
| Electric current / 1 pc. | 3 A |
| RoHS2 corresponding | ○ |
| type | BNC |
|---|---|
| Connection type | The atmosphere-side plug-fitti |
| electrode | Kovar ® |
| Flange material | SUS 304 |
| sleeve | Kovar ® |
| Insulator | Alumina ceramic |
| Maximum temperature | 450℃ |
| The lowest temperature | -196℃ |
| Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
| Classification | Flanged terminal |
| type | Ground shield |
| Impedance | 50 Ω |
| frequency | 100 MHz |
| Insulation resistance value | 10⁹ ohm |
| Withstand voltage: DC | 5 kV |
| Electric current / 1 pc. | 3 A |
| RoHS2 corresponding | ○ |
| type | BNC |
|---|---|
| Connection type | The atmosphere-side plug-fitti |
| electrode | Kovar ® |
| Flange material | SUS 304 |
| sleeve | Kovar ® |
| Insulator | Alumina ceramic |
| Maximum temperature | 450℃ |
| The lowest temperature | -196℃ |
| Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
| Classification | Flanged terminal |
| type | Floating shield |
| Impedance | 50 Ω |
| frequency | 100 MHz |
| Insulation resistance value | 10⁹ ohm |
| Withstand voltage: DC | 1 kV |
| Electric current / 1 pc. | 3 A |
| RoHS2 corresponding | ○ |
| type | BNC |
|---|---|
| Connection type | The atmosphere-side plug-fitti |
| electrode | Kovar ® |
| Flange material | SUS 304 |
| sleeve | Kovar ® |
| Insulator | Alumina ceramic |
| Maximum temperature | 450℃ |
| The lowest temperature | -196℃ |
| Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
| Classification | Flanged terminal |
| type | Floating shield |
| Impedance | 50 Ω |
| frequency | 100 MHz |
| Insulation resistance value | 10⁹ ohm |
| Withstand voltage: DC | 1 kV |
| Electric current / 1 pc. | 3 A |
| RoHS2 corresponding | ○ |