type | High Voltage RF |
---|---|
electrode | Oxygen-free copper |
Flange material | SUS 304 |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -100℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Withstand voltage: DC | 8 kV |
Electric current / 1 pc. | N/A |
Feedthrough | 8 kV |
type | High Voltage RF |
---|---|
electrode | Oxygen-free copper |
Flange material | SUS 304 |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -100℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Withstand voltage: DC | 10 kV |
Electric current / 1 pc. | N/A |
Feedthrough | 10 kV |
type | Water-cooled terminal |
---|---|
Flange material | SUS 304 |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Insulation resistance value | 10⁹ ohm |
type | Low voltage and medium current |
---|---|
electrode | molybdenum (Mo) |
Flange material | SUS 304 |
Maximum temperature | 450℃ |
The lowest temperature | -100℃ |
Leak rate | <1x10<sup>-8</sup>Pa・㎥/sec |
Withstand voltage: DC | 700 V |
Electric current / 1 pc. | 28 A |
Connection type | MS |
type | High-voltage and medium curren |
---|---|
electrode | Oxygen-free copper |
Flange material | SUS 304 |
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Insulation resistance value | 10⁹ ohm |
Withstand voltage: DC | 3 kV |
Electric current / 1 pc. | 35 A |
Feedthrough | 3 kV / 35 A |
type | High-voltage and medium curren |
---|---|
electrode | Oxygen-free copper + Ni platin |
Flange material | SUS 304 |
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Insulation resistance value | 10⁹ ohm |
Withstand voltage: DC | 3 kV |
Electric current / 1 pc. | 35 A |
Feedthrough | 3 kV / 35 A |
type | High-voltage and medium curren |
---|---|
electrode | Oxygen-free copper |
Flange material | SUS 304 |
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Insulation resistance value | 10⁹ ohm |
Withstand voltage: DC | 3 kV |
Electric current / 1 pc. | 35 A |
Feedthrough | 3 kV / 35 A |
type | High voltage and high current |
---|---|
electrode | Oxygen-free copper |
Flange material | SUS 304 |
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Insulation resistance value | 10⁹ ohm |
Withstand voltage: DC | 5 kV |
Electric current / 1 pc. | 110 A |
Feedthrough | 5 kV / 110 A |
type | High voltage and high current |
---|---|
electrode | Oxygen-free copper |
Flange material | SUS 304 |
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Insulation resistance value | 10⁹ ohm |
Withstand voltage: DC | 5 kV |
Electric current / 1 pc. | 110 A |
Feedthrough | 5 kV / 110 A |
type | High voltage and high current |
---|---|
Feedthrough | 5 kV / 110 A |
Electric current / 1 pc. | 110 A |
Withstand voltage: DC | 5 kV |
Insulation resistance value | 10⁹ ohm |
electrode | Oxygen-free copper |
Flange material | SUS 304 |
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
type | High voltage and high current |
---|---|
electrode | Oxygen-free copper + Ni platin |
Flange material | SUS 304 |
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Insulation resistance value | 10⁹ ohm |
Withstand voltage: DC | 5 kV |
Electric current / 1 pc. | 110 A |
Feedthrough | 5 kV / 110 A |
Flange material | SUS 304 |
---|---|
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Insulation resistance value | 10⁹ ohm |
Withstand voltage: DC | 5 kV |
Flange material | SUS 304 |
---|---|
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Insulation resistance value | 10⁹ ohm |
Withstand voltage: DC | 5 kV |
The number of electrode | 1 |
Flange material | SUS 304 |
---|---|
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Insulation resistance value | 10⁹ ohm |
Withstand voltage: DC | 5 kV |
The number of electrode | 1 |
type | High-voltage and medium curren |
---|---|
electrode | Oxygen-free copper |
Flange material | SUS 304 |
sleeve | SUS 430 |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Insulation resistance value | 10⁹ ohm |
Withstand voltage: DC | 5 kV |
Electric current / 1 pc. | 22 A |
Feedthrough | 5 kV / 22 A |
type | High voltage and low current |
---|---|
electrode | SUS 304 |
Flange material | SUS 304 |
sleeve | SUS 430 |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Insulation resistance value | 10⁹ ohm |
Withstand voltage: DC | 5 kV |
Electric current / 1 pc. | 3 A |
Feedthrough | 5 kV / 3 A |
type | High voltage and high current |
---|---|
electrode | Oxygen-free copper |
Flange material | SUS 304 |
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Insulation resistance value | 10⁹ ohm |
Withstand voltage: DC | 6 kV |
Electric current / 1 pc. | 145 A |
Feedthrough | 6 kV / 145 A |
Flange material | SUS 304 |
---|---|
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Insulation resistance value | 10⁹ ohm |
Withstand voltage: DC | 10 kV |
The number of electrode | 1 |
Flange material | SUS 304 |
---|---|
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Insulation resistance value | 10⁹ ohm |
Withstand voltage: DC | 10 kV |
The number of electrode | 1 |