About 10,000 types of vacuum components in stock at all times.Business Hours: 9:00-18:00, excluding weekends and holidays
Maximum temperature | 200℃ |
---|---|
external material | PTFE100% |
internal material | PTFE100% |
heat insulating material | Glass mat t=10mm |
Heater wire diameter | Φ2.2 |
▼Ribbon heaters for clean rooms
Clean room compatible
No dust due to the use of PTFE coated cloth on the exterior
No generation of siloxane gas
Power connection: 100V outlet included
▼UL listed ribbon heater
UL listed
Clean room compatible
Exterior: 100% PTFE
Power connection: with lead wire (left uncut)
▼Features
Threaded wire is hard to be broken.
Heater wire with insulation coating is used, and double insulation is applied to the exterior, so there is no risk of shorts between wires.
▼Others
If the excess portion is left floating, it may shorten the service life of the product. It is recommended to insulate with glass mat, etc.
・For other precautions, please refer to the following link
Ribbon heater handling notes.
Heater wire diameter | Φ2.2 |
---|---|
Withstand voltage (AC) | 100 V |
Electric capacity (W) | 97 |
B (amplitude) | 20 |
L | 1000 |
UL Standard | - |
Maximum temperature | 260℃ |
Connection type | コンセント |
external material | PTFE coated cloth |
▼Ribbon heaters for clean rooms
Clean room compatible
No dust due to the use of PTFE coated cloth on the exterior
No generation of siloxane gas
Power connection: 100V outlet included
▼UL listed ribbon heater
UL listed
Clean room compatible
Exterior: 100% PTFE
Power connection: with lead wire (left uncut)
▼Features
Threaded wire is hard to be broken.
Heater wire with insulation coating is used, and double insulation is applied to the exterior, so there is no risk of shorts between wires.
▼Others
If the excess portion is left floating, it may shorten the service life of the product. It is recommended to insulate with glass mat, etc.
・For other precautions, please refer to the following link
Ribbon heater handling notes.
Heater wire diameter | Φ2.2 |
---|---|
Withstand voltage (AC) | 100 V |
Electric capacity (W) | 211 |
B (amplitude) | 20 |
L | 2000 |
UL Standard | - |
Maximum temperature | 260℃ |
Connection type | コンセント |
external material | PTFE coated cloth |
▼Ribbon heaters for clean rooms
Clean room compatible
No dust due to the use of PTFE coated cloth on the exterior
No generation of siloxane gas
Power connection: 100V outlet included
▼UL listed ribbon heater
UL listed
Clean room compatible
Exterior: 100% PTFE
Power connection: with lead wire (left uncut)
▼Features
Threaded wire is hard to be broken.
Heater wire with insulation coating is used, and double insulation is applied to the exterior, so there is no risk of shorts between wires.
▼Others
If the excess portion is left floating, it may shorten the service life of the product. It is recommended to insulate with glass mat, etc.
・For other precautions, please refer to the following link
Ribbon heater handling notes.
Heater wire diameter | Φ2.2 |
---|---|
Withstand voltage (AC) | 100 V |
Electric capacity (W) | 309 |
B (amplitude) | 20 |
L | 3000 |
UL Standard | - |
Maximum temperature | 260℃ |
Connection type | コンセント |
external material | PTFE coated cloth |
▼Ribbon heaters for clean rooms
Clean room compatible
No dust due to the use of PTFE coated cloth on the exterior
No generation of siloxane gas
Power connection: 100V outlet included
▼UL listed ribbon heater
UL listed
Clean room compatible
Exterior: 100% PTFE
Power connection: with lead wire (left uncut)
▼Features
Threaded wire is hard to be broken.
Heater wire with insulation coating is used, and double insulation is applied to the exterior, so there is no risk of shorts between wires.
▼Others
If the excess portion is left floating, it may shorten the service life of the product. It is recommended to insulate with glass mat, etc.
・For other precautions, please refer to the following link
Ribbon heater handling notes.
Heater wire diameter | Φ2.2 |
---|---|
Withstand voltage (AC) | 100 V |
Electric capacity (W) | 97 |
B (amplitude) | 30 |
L | 1000 |
UL Standard | - |
Maximum temperature | 260℃ |
Connection type | コンセント |
external material | PTFE coated cloth |
▼Ribbon heaters for clean rooms
Clean room compatible
No dust due to the use of PTFE coated cloth on the exterior
No generation of siloxane gas
Power connection: 100V outlet included
▼UL listed ribbon heater
UL listed
Clean room compatible
Exterior: 100% PTFE
Power connection: with lead wire (left uncut)
▼Features
Threaded wire is hard to be broken.
Heater wire with insulation coating is used, and double insulation is applied to the exterior, so there is no risk of shorts between wires.
▼Others
If the excess portion is left floating, it may shorten the service life of the product. It is recommended to insulate with glass mat, etc.
・For other precautions, please refer to the following link
Ribbon heater handling notes.
Heater wire diameter | Φ2.2 |
---|---|
Withstand voltage (AC) | 100 V |
Electric capacity (W) | 211 |
B (amplitude) | 30 |
L | 2000 |
UL Standard | - |
Maximum temperature | 260℃ |
Connection type | コンセント |
external material | PTFE coated cloth |
▼Ribbon heaters for clean rooms
Clean room compatible
No dust due to the use of PTFE coated cloth on the exterior
No generation of siloxane gas
Power connection: 100V outlet included
▼UL listed ribbon heater
UL listed
Clean room compatible
Exterior: 100% PTFE
Power connection: with lead wire (left uncut)
▼Features
Threaded wire is hard to be broken.
Heater wire with insulation coating is used, and double insulation is applied to the exterior, so there is no risk of shorts between wires.
▼Others
If the excess portion is left floating, it may shorten the service life of the product. It is recommended to insulate with glass mat, etc.
・For other precautions, please refer to the following link
Ribbon heater handling notes.
Heater wire diameter | Φ2.2 |
---|---|
Withstand voltage (AC) | 100 V |
Electric capacity (W) | 309 |
B (amplitude) | 30 |
L | 3000 |
UL Standard | - |
Maximum temperature | 260℃ |
Connection type | コンセント |
external material | PTFE coated cloth |
▼Ribbon heaters for clean rooms
Clean room compatible
No dust due to the use of PTFE coated cloth on the exterior
No generation of siloxane gas
Power connection: 100V outlet included
▼UL listed ribbon heater
UL listed
Clean room compatible
Exterior: 100% PTFE
Power connection: with lead wire (left uncut)
▼Features
Threaded wire is hard to be broken.
Heater wire with insulation coating is used, and double insulation is applied to the exterior, so there is no risk of shorts between wires.
▼Others
If the excess portion is left floating, it may shorten the service life of the product. It is recommended to insulate with glass mat, etc.
・For other precautions, please refer to the following link
Ribbon heater handling notes.
Heater wire diameter | Φ2.2 |
---|---|
Withstand voltage (AC) | 100 V |
Electric capacity (W) | 103 |
B (amplitude) | 50 |
L | 1000 |
UL Standard | - |
Maximum temperature | 260℃ |
Connection type | コンセント |
external material | PTFE coated cloth |
▼Ribbon heaters for clean rooms
Clean room compatible
No dust due to the use of PTFE coated cloth on the exterior
No generation of siloxane gas
Power connection: 100V outlet included
▼UL listed ribbon heater
UL listed
Clean room compatible
Exterior: 100% PTFE
Power connection: with lead wire (left uncut)
▼Features
Threaded wire is hard to be broken.
Heater wire with insulation coating is used, and double insulation is applied to the exterior, so there is no risk of shorts between wires.
▼Others
If the excess portion is left floating, it may shorten the service life of the product. It is recommended to insulate with glass mat, etc.
・For other precautions, please refer to the following link
Ribbon heater handling notes.
Heater wire diameter | Φ2.2 |
---|---|
Withstand voltage (AC) | 100 V |
Electric capacity (W) | 217 |
B (amplitude) | 50 |
L | 2000 |
UL Standard | - |
Maximum temperature | 260℃ |
Connection type | コンセント |
external material | PTFE coated cloth |
▼Ribbon heaters for clean rooms
Clean room compatible
No dust due to the use of PTFE coated cloth on the exterior
No generation of siloxane gas
Power connection: 100V outlet included
▼UL listed ribbon heater
UL listed
Clean room compatible
Exterior: 100% PTFE
Power connection: with lead wire (left uncut)
▼Features
Threaded wire is hard to be broken.
Heater wire with insulation coating is used, and double insulation is applied to the exterior, so there is no risk of shorts between wires.
▼Others
If the excess portion is left floating, it may shorten the service life of the product. It is recommended to insulate with glass mat, etc.
・For other precautions, please refer to the following link
Ribbon heater handling notes.
Heater wire diameter | Φ2.2 |
---|---|
Withstand voltage (AC) | 100 V |
Electric capacity (W) | 325 |
B (amplitude) | 50 |
L | 3000 |
UL Standard | - |
Maximum temperature | 260℃ |
Connection type | コンセント |
external material | PTFE coated cloth |
▼Ribbon heaters for clean rooms
Clean room compatible
No dust due to the use of PTFE coated cloth on the exterior
No generation of siloxane gas
Power connection: 100V outlet included
▼UL listed ribbon heater
UL listed
Clean room compatible
Exterior: 100% PTFE
Power connection: with lead wire (left uncut)
▼Features
Threaded wire is hard to be broken.
Heater wire with insulation coating is used, and double insulation is applied to the exterior, so there is no risk of shorts between wires.
▼Others
If the excess portion is left floating, it may shorten the service life of the product. It is recommended to insulate with glass mat, etc.
・For other precautions, please refer to the following link
Ribbon heater handling notes.
Heater wire diameter | Φ2.2 |
---|---|
Withstand voltage (AC) | 100 V |
Electric capacity (W) | 97 |
B (amplitude) | 20 |
UL Standard | 〇 |
Connection type | untouched |
external material | PTFE100% |
L | 1000 |
Maximum temperature | 180℃ |
▼Ribbon heaters for clean rooms
Clean room compatible
No dust due to the use of PTFE coated cloth on the exterior
No generation of siloxane gas
Power connection: 100V outlet included
▼UL listed ribbon heater
UL listed
Clean room compatible
Exterior: 100% PTFE
Power connection: with lead wire (left uncut)
▼Features
Threaded wire is hard to be broken.
Heater wire with insulation coating is used, and double insulation is applied to the exterior, so there is no risk of shorts between wires.
▼Others
If the excess portion is left floating, it may shorten the service life of the product. It is recommended to insulate with glass mat, etc.
・For other precautions, please refer to the following link
Ribbon heater handling notes.
Heater wire diameter | Φ2.2 |
---|---|
Withstand voltage (AC) | 100 V |
Electric capacity (W) | 137 |
B (amplitude) | 20 |
UL Standard | 〇 |
Connection type | untouched |
external material | PTFE100% |
L | 1500 |
Maximum temperature | 180℃ |
▼Ribbon heaters for clean rooms
Clean room compatible
No dust due to the use of PTFE coated cloth on the exterior
No generation of siloxane gas
Power connection: 100V outlet included
▼UL listed ribbon heater
UL listed
Clean room compatible
Exterior: 100% PTFE
Power connection: with lead wire (left uncut)
▼Features
Threaded wire is hard to be broken.
Heater wire with insulation coating is used, and double insulation is applied to the exterior, so there is no risk of shorts between wires.
▼Others
If the excess portion is left floating, it may shorten the service life of the product. It is recommended to insulate with glass mat, etc.
・For other precautions, please refer to the following link
Ribbon heater handling notes.
Heater wire diameter | Φ2.2 |
---|---|
Withstand voltage (AC) | 100 V |
Electric capacity (W) | 211 |
B (amplitude) | 20 |
UL Standard | 〇 |
Connection type | untouched |
external material | PTFE100% |
L | 2000 |
Maximum temperature | 180℃ |
▼Ribbon heaters for clean rooms
Clean room compatible
No dust due to the use of PTFE coated cloth on the exterior
No generation of siloxane gas
Power connection: 100V outlet included
▼UL listed ribbon heater
UL listed
Clean room compatible
Exterior: 100% PTFE
Power connection: with lead wire (left uncut)
▼Features
Threaded wire is hard to be broken.
Heater wire with insulation coating is used, and double insulation is applied to the exterior, so there is no risk of shorts between wires.
▼Others
If the excess portion is left floating, it may shorten the service life of the product. It is recommended to insulate with glass mat, etc.
・For other precautions, please refer to the following link
Ribbon heater handling notes.
Heater wire diameter | Φ2.2 |
---|---|
Withstand voltage (AC) | 100 V |
Electric capacity (W) | 232 |
B (amplitude) | 20 |
UL Standard | 〇 |
Connection type | untouched |
external material | PTFE100% |
L | 2500 |
Maximum temperature | 180℃ |
▼Ribbon heaters for clean rooms
Clean room compatible
No dust due to the use of PTFE coated cloth on the exterior
No generation of siloxane gas
Power connection: 100V outlet included
▼UL listed ribbon heater
UL listed
Clean room compatible
Exterior: 100% PTFE
Power connection: with lead wire (left uncut)
▼Features
Threaded wire is hard to be broken.
Heater wire with insulation coating is used, and double insulation is applied to the exterior, so there is no risk of shorts between wires.
▼Others
If the excess portion is left floating, it may shorten the service life of the product. It is recommended to insulate with glass mat, etc.
・For other precautions, please refer to the following link
Ribbon heater handling notes.
Heater wire diameter | Φ2.2 |
---|---|
Withstand voltage (AC) | 100 V |
Electric capacity (W) | 309 |
B (amplitude) | 20 |
UL Standard | 〇 |
Connection type | untouched |
external material | PTFE100% |
L | 3000 |
Maximum temperature | 180℃ |
▼Ribbon heaters for clean rooms
Clean room compatible
No dust due to the use of PTFE coated cloth on the exterior
No generation of siloxane gas
Power connection: 100V outlet included
▼UL listed ribbon heater
UL listed
Clean room compatible
Exterior: 100% PTFE
Power connection: with lead wire (left uncut)
▼Features
Threaded wire is hard to be broken.
Heater wire with insulation coating is used, and double insulation is applied to the exterior, so there is no risk of shorts between wires.
▼Others
If the excess portion is left floating, it may shorten the service life of the product. It is recommended to insulate with glass mat, etc.
・For other precautions, please refer to the following link
Ribbon heater handling notes.
Heater wire diameter | Φ2.2 |
---|---|
Withstand voltage (AC) | 100 V |
Electric capacity (W) | 97 |
B (amplitude) | 30 |
UL Standard | 〇 |
Connection type | untouched |
external material | PTFE100% |
L | 1000 |
Maximum temperature | 180℃ |
▼Ribbon heaters for clean rooms
Clean room compatible
No dust due to the use of PTFE coated cloth on the exterior
No generation of siloxane gas
Power connection: 100V outlet included
▼UL listed ribbon heater
UL listed
Clean room compatible
Exterior: 100% PTFE
Power connection: with lead wire (left uncut)
▼Features
Threaded wire is hard to be broken.
Heater wire with insulation coating is used, and double insulation is applied to the exterior, so there is no risk of shorts between wires.
▼Others
If the excess portion is left floating, it may shorten the service life of the product. It is recommended to insulate with glass mat, etc.
・For other precautions, please refer to the following link
Ribbon heater handling notes.
Heater wire diameter | Φ2.2 |
---|---|
Withstand voltage (AC) | 100 V |
Electric capacity (W) | 137 |
B (amplitude) | 30 |
UL Standard | 〇 |
Connection type | untouched |
external material | PTFE100% |
L | 1500 |
Maximum temperature | 180℃ |
▼Ribbon heaters for clean rooms
Clean room compatible
No dust due to the use of PTFE coated cloth on the exterior
No generation of siloxane gas
Power connection: 100V outlet included
▼UL listed ribbon heater
UL listed
Clean room compatible
Exterior: 100% PTFE
Power connection: with lead wire (left uncut)
▼Features
Threaded wire is hard to be broken.
Heater wire with insulation coating is used, and double insulation is applied to the exterior, so there is no risk of shorts between wires.
▼Others
If the excess portion is left floating, it may shorten the service life of the product. It is recommended to insulate with glass mat, etc.
・For other precautions, please refer to the following link
Ribbon heater handling notes.
Heater wire diameter | Φ2.2 |
---|---|
Withstand voltage (AC) | 100 V |
Electric capacity (W) | 211 |
B (amplitude) | 30 |
UL Standard | 〇 |
Connection type | untouched |
external material | PTFE100% |
L | 2000 |
Maximum temperature | 180℃ |
▼Ribbon heaters for clean rooms
Clean room compatible
No dust due to the use of PTFE coated cloth on the exterior
No generation of siloxane gas
Power connection: 100V outlet included
▼UL listed ribbon heater
UL listed
Clean room compatible
Exterior: 100% PTFE
Power connection: with lead wire (left uncut)
▼Features
Threaded wire is hard to be broken.
Heater wire with insulation coating is used, and double insulation is applied to the exterior, so there is no risk of shorts between wires.
▼Others
If the excess portion is left floating, it may shorten the service life of the product. It is recommended to insulate with glass mat, etc.
・For other precautions, please refer to the following link
Ribbon heater handling notes.
Heater wire diameter | Φ2.2 |
---|---|
Withstand voltage (AC) | 100 V |
Electric capacity (W) | 232 |
B (amplitude) | 30 |
UL Standard | 〇 |
Connection type | untouched |
external material | PTFE100% |
L | 2500 |
Maximum temperature | 180℃ |
▼Ribbon heaters for clean rooms
Clean room compatible
No dust due to the use of PTFE coated cloth on the exterior
No generation of siloxane gas
Power connection: 100V outlet included
▼UL listed ribbon heater
UL listed
Clean room compatible
Exterior: 100% PTFE
Power connection: with lead wire (left uncut)
▼Features
Threaded wire is hard to be broken.
Heater wire with insulation coating is used, and double insulation is applied to the exterior, so there is no risk of shorts between wires.
▼Others
If the excess portion is left floating, it may shorten the service life of the product. It is recommended to insulate with glass mat, etc.
・For other precautions, please refer to the following link
Ribbon heater handling notes.
Heater wire diameter | Φ2.2 |
---|---|
Withstand voltage (AC) | 100 V |
Electric capacity (W) | 309 |
B (amplitude) | 30 |
UL Standard | 〇 |
Connection type | untouched |
external material | PTFE100% |
L | 3000 |
Maximum temperature | 180℃ |
▼Film sheet heater
Sheet heater using chemical-resistant polyimide film
No dust emission, recommended for use in clean rooms
Can be used under vacuum.
Ultrathin design with a thickness of only 0.1 mm, allowing use in limited space.
Lead wire: Silicon coated (uncut), 200mm long
Mounting method can be selected according to the environment, such as screw mounting or adhesive bonding.
▼We can customize it for you!
High heat-resistance type is available for normal temperature of 300℃ and maximum of 350℃ by special processing.
Shapes and dimensions can be customized freely according to your needs.
▼Others
If you have any questions about our products, please feel free to contact us from the "Inquiry" button.
Heater wire diameter | Φ2.0 |
---|---|
Electric capacity (W) | 50 |
The outer diameter (mm) | 50 x 50 |
Dimensions of heating element | 50 x 50 |
Withstand voltage (AC) | 100 V |
Maximum temperature | 200℃ |