Isolator Product List Isolator

Subcategory 6Matter (1 ~6 )

Products 161Matter (1 ~20 )

Displayed results
Display switching
  • Product code :18875
    Model:TE1/16ISL2KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 1/16 inch
    L 34
    Withstand voltage: DC 2 kV
    sleeve 70-30 CuNi
    57,100JPY (with tax 62,810JPY)
    Inquiry for this product
  • Product code :11307
    Model:TE1/8ISL3KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 1/8 inch
    L 47
    Withstand voltage: DC 3 kV
    sleeve 70-30 CuNi
    29,400JPY (with tax 32,340JPY)
    Inquiry for this product
  • Product code :13013
    Model:TE1/4ISL1KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 1/4 inch
    L 25
    Withstand voltage: DC 1.8 kV
    sleeve Kovar ®
    19,000JPY (with tax 20,900JPY)
    Inquiry for this product
  • Product code :10156
    Model:TE1/4ISL10KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 1/4 inch
    L 78
    Withstand voltage: DC 10 kV
    sleeve SUS 304
    19,600JPY (with tax 21,560JPY)
    Inquiry for this product
  • Product code :10420
    Model:TE1/2ISL10KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 1/2 inch
    L 70
    Withstand voltage: DC 10 kV
    sleeve Kovar ®
    64,000JPY (with tax 70,400JPY)
    Inquiry for this product
  • Product code :16709
    Model:TE3/4ISL30KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 3/4 inch
    L 91.4
    Withstand voltage: DC 30 kV
    sleeve SUS 304
    86,500JPY (with tax 95,150JPY)
    Inquiry for this product
  • Product code :16710
    Model:TE1-1/2ISL30KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 1-1/2 inch
    L 96.5
    Withstand voltage: DC 30 kV
    sleeve SUS 304
    59,900JPY (with tax 65,890JPY)
    Inquiry for this product
  • Product code :16711
    Model:TE2-3/8ISL30KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 2-3/8 inch
    L 85.3
    Withstand voltage: DC 30 kV
    sleeve SUS 304
    156,400JPY (with tax 172,040JPY)
    Inquiry for this product
  • Product code :16719
    Model:TE2-4/5ISL40KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 2-4/5 inch
    L 110.7
    Withstand voltage: DC 40 kV
    sleeve SUS 304
    172,200JPY (with tax 189,420JPY)
    Inquiry for this product
  • Product code :16721
    Model:TE1-1/2ISL60KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 1-1/2 inch
    L 149.9
    Withstand voltage: DC 60 kV
    sleeve SUS 304
    106,700JPY (with tax 117,370JPY)
    Inquiry for this product
  • Product code :18675
    Model:TE16.4ISL6KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 16.4 mm
    Φ D1 25
    Φ D2 14
    Φ D3 15.4
    Φ D4 16.4
    L 52
    L1 10
    Withstand voltage: DC 6 kV
    sleeve Kovar ®
    58,900JPY (with tax 64,790JPY)
    Inquiry for this product
  • Product code :18676
    Model:TE16.4ISL12KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 16.4 mm
    Φ D1 25
    Φ D2 14
    Φ D3 15.4
    Φ D4 16.4
    L 62
    L1 20
    Withstand voltage: DC 12 kV
    sleeve Kovar ®
    63,400JPY (with tax 69,740JPY)
    Inquiry for this product
  • Product code :60145
    Model:60145

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 19 mm
    L 48
    Withstand voltage: DC 6 kV
    sleeve SUS 304
    30,700JPY (with tax 33,770JPY)
    Inquiry for this product
  • Product code :18677
    Model:TE30ISL12KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 30 mm
    Φ D1 42
    Φ D2 27
    Φ D3 29
    Φ D4 30
    L 54
    L1 20
    Withstand voltage: DC 12 kV
    sleeve Kovar ®
    86,600JPY (with tax 95,260JPY)
    Inquiry for this product
  • Product code :18678
    Model:TE30ISL24KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 30 mm
    Φ D1 42
    Φ D2 27
    Φ D3 29
    Φ D4 30
    L 74
    L1 40
    Withstand voltage: DC 24 kV
    sleeve Kovar ®
    93,800JPY (with tax 103,180JPY)
    Inquiry for this product
  • Product code :60160
    Model:60160

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 31.75 mm
    Withstand voltage: DC 20 kV
    sleeve Kovar ®
    31,400JPY (with tax 34,540JPY)
    Inquiry for this product
  • Product code :60126
    Model:60126

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 31.75 mm
    Withstand voltage: DC 35 kV
    sleeve Kovar ®
    22,300JPY (with tax 24,530JPY)
    Inquiry for this product
  • Product code :60127
    Model:60127

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 31.75 mm
    Withstand voltage: DC 65 kV
    sleeve Kovar ®
    49,700JPY (with tax 54,670JPY)
    Inquiry for this product
  • Product code :60125
    Model:60125

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 51 mm
    Withstand voltage: DC 40 kV
    sleeve Kovar ®
    74,600JPY (with tax 82,060JPY)
    Inquiry for this product
  • Product code :18679
    Model:TE59.5ISL12KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 59.5 mm
    Φ D1 70
    Φ D2 56
    Φ D3 58.5
    Φ D4 59.5
    L 72
    L1 20
    Withstand voltage: DC 12 kV
    sleeve Kovar ®
    146,400JPY (with tax 161,040JPY)
    Inquiry for this product
Shipping accepted on the day on orders until 17:00 Hours 9:00 to 18:00 except Saturdays, Sundays, and holidays
Contact Us
Please fill in the form below.
After confirming the content of your enquiry,
a representative will contact you.

To use this service, please login or register as a member.

Not a member yet?

Registering as a member gives you access to a number of useful features.

ぜひご登録ください!

※ Please note that it may take several days after applying for a member registration until the registration is complete. Please note that we reserve the right to refuse your application at our discretion.