About 8,000 types of vacuum components in stock at all times.Business Hours: 9:00-18:00, excluding weekends and holidays

Product Category
  • Feedthrough Feedthrough
    Feedthrough
  • Isolator Isolator
    Isolator
  • Viewport Viewport
    Viewport
  • Vacuum Component Vacuum Component
    Vacuum Component
  • Vacuum Valve Vacuum Valve
    Vacuum Valve
  • Vented Screw Vented Screw
    Vented Screw
  • Others Others
    Others
  1. Cosmotec for Vacuum Components
  2. Feedthrough
  3. Thermocouple
  4. K Thermocouple
  5. Feedthrough K thermocouple BURNDY® Type Combination

Feedthrough K thermocouple BURNDY® Type Combination Product List Feedthrough

Products 94Matter (41 ~60 )

Displayed results
Display switching
  • Product code :40927
    Model:F50TCK2WP4GA

    ▼ Thermocouple BURNDY K type 2 pairs + current induction terminal 4PIN
    Mates with bayonet locking plug
    K type (Chromel®Almel®) thermocouple terminals for temperature measurement
    Copper electrode: 20A compatible
    Power induction and thermal measurement in one port
    Easy connection by simply inserting along the guide groove even in difficult-to-see locations
    In addition to vacuum/atmosphere side connection parts and tools, we also offer pre-assembled products and assembly services (pre-assembled products: for vacuum side/For Atmospheric side)
    ※Thermocouple electrodes are designed for thermal measurement, so there is no reference data for withstand current value.

    ▼The following types are standardized
    K type 1 pair / 2PIN current introduction terminal
    K type 2 pair / current introduction terminal 4PIN
    Flange: NW/KF, ICF, JIS-VF, JIS-VG

    ▼Custom-made products are also available.
    We can also accept a combination of multiple different types of terminals, flange size changes, and mounting on special flanges.
    Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning request, please click here.

    The number of electrode 4
    Pairs of Thermocouple 2
    type K Thermocouple / cable termina
    Electric current / 1 pc. 20 A
    Total current/1 terminal Milli
    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    electrode Chromel ® / alumel ® / oxygen-
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 50
    A 120
    B 10
    D 47
    The contents of goods Only flanged terminal
  • Product code :40928
    Model:F50TCK2WP4GUT1B

    ▼ Thermocouple BURNDY K type 2 pairs + current induction terminal 4PIN
    Mates with bayonet locking plug
    K type (Chromel®Almel®) thermocouple terminals for temperature measurement
    Copper electrode: 20A compatible
    Power induction and thermal measurement in one port
    Easy connection by simply inserting along the guide groove even in difficult-to-see locations
    In addition to vacuum/atmosphere side connection parts and tools, we also offer pre-assembled products and assembly services (pre-assembled products: for vacuum side/For Atmospheric side)
    ※Thermocouple electrodes are designed for thermal measurement, so there is no reference data for withstand current value.

    ▼The following types are standardized
    K type 1 pair / 2PIN current introduction terminal
    K type 2 pair / current introduction terminal 4PIN
    Flange: NW/KF, ICF, JIS-VF, JIS-VG

    ▼Custom-made products are also available.
    We can also accept a combination of multiple different types of terminals, flange size changes, and mounting on special flanges.
    Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning request, please click here.

    The number of electrode 4
    Pairs of Thermocouple 2
    type K Thermocouple / cable termina
    Electric current / 1 pc. 20 A
    Total current/1 terminal Milli
    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    electrode Chromel ® / alumel ® / oxygen-
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 50
    A 120
    B 10
    D 47
    The contents of goods Assembled set
  • Product code :40929
    Model:G20TCK2WP4GA

    ▼ Thermocouple BURNDY K type 2 pairs + current induction terminal 4PIN
    Mates with bayonet locking plug
    K type (Chromel®Almel®) thermocouple terminals for temperature measurement
    Copper electrode: 20A compatible
    Power induction and thermal measurement in one port
    Easy connection by simply inserting along the guide groove even in difficult-to-see locations
    In addition to vacuum/atmosphere side connection parts and tools, we also offer pre-assembled products and assembly services (pre-assembled products: for vacuum side/For Atmospheric side)
    ※Thermocouple electrodes are designed for thermal measurement, so there is no reference data for withstand current value.

    ▼The following types are standardized
    K type 1 pair / 2PIN current introduction terminal
    K type 2 pair / current introduction terminal 4PIN
    Flange: NW/KF, ICF, JIS-VF, JIS-VG

    ▼Custom-made products are also available.
    We can also accept a combination of multiple different types of terminals, flange size changes, and mounting on special flanges.
    Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning request, please click here.

    The number of electrode 4
    Pairs of Thermocouple 2
    type K Thermocouple / cable termina
    Electric current / 1 pc. 20 A
    Total current/1 terminal Milli
    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    electrode Chromel ® / alumel ® / oxygen-
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VG 20
    A 80
    B 8
    D 45
    The contents of goods Only flanged terminal
  • Product code :40930
    Model:G20TCK2WP4GUT1B

    ▼ Thermocouple BURNDY K type 2 pairs + current induction terminal 4PIN
    Mates with bayonet locking plug
    K type (Chromel®Almel®) thermocouple terminals for temperature measurement
    Copper electrode: 20A compatible
    Power induction and thermal measurement in one port
    Easy connection by simply inserting along the guide groove even in difficult-to-see locations
    In addition to vacuum/atmosphere side connection parts and tools, we also offer pre-assembled products and assembly services (pre-assembled products: for vacuum side/For Atmospheric side)
    ※Thermocouple electrodes are designed for thermal measurement, so there is no reference data for withstand current value.

    ▼The following types are standardized
    K type 1 pair / 2PIN current introduction terminal
    K type 2 pair / current introduction terminal 4PIN
    Flange: NW/KF, ICF, JIS-VF, JIS-VG

    ▼Custom-made products are also available.
    We can also accept a combination of multiple different types of terminals, flange size changes, and mounting on special flanges.
    Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning request, please click here.

    The number of electrode 4
    Pairs of Thermocouple 2
    type K Thermocouple / cable termina
    Electric current / 1 pc. 20 A
    Total current/1 terminal Milli
    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    electrode Chromel ® / alumel ® / oxygen-
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VG 20
    A 80
    B 8
    D 45
    The contents of goods Assembled set
  • Product code :40931
    Model:G25TCK2WP4GA

    ▼ Thermocouple BURNDY K type 2 pairs + current induction terminal 4PIN
    Mates with bayonet locking plug
    K type (Chromel®Almel®) thermocouple terminals for temperature measurement
    Copper electrode: 20A compatible
    Power induction and thermal measurement in one port
    Easy connection by simply inserting along the guide groove even in difficult-to-see locations
    In addition to vacuum/atmosphere side connection parts and tools, we also offer pre-assembled products and assembly services (pre-assembled products: for vacuum side/For Atmospheric side)
    ※Thermocouple electrodes are designed for thermal measurement, so there is no reference data for withstand current value.

    ▼The following types are standardized
    K type 1 pair / 2PIN current introduction terminal
    K type 2 pair / current introduction terminal 4PIN
    Flange: NW/KF, ICF, JIS-VF, JIS-VG

    ▼Custom-made products are also available.
    We can also accept a combination of multiple different types of terminals, flange size changes, and mounting on special flanges.
    Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning request, please click here.

    The number of electrode 4
    Pairs of Thermocouple 2
    type K Thermocouple / cable termina
    Electric current / 1 pc. 20 A
    Total current/1 terminal Milli
    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    electrode Chromel ® / alumel ® / oxygen-
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VG 25
    A 90
    B 8
    D 45
    The contents of goods Only flanged terminal
  • Product code :40932
    Model:G25TCK2WP4GUT1B

    ▼ Thermocouple BURNDY K type 2 pairs + current induction terminal 4PIN
    Mates with bayonet locking plug
    K type (Chromel®Almel®) thermocouple terminals for temperature measurement
    Copper electrode: 20A compatible
    Power induction and thermal measurement in one port
    Easy connection by simply inserting along the guide groove even in difficult-to-see locations
    In addition to vacuum/atmosphere side connection parts and tools, we also offer pre-assembled products and assembly services (pre-assembled products: for vacuum side/For Atmospheric side)
    ※Thermocouple electrodes are designed for thermal measurement, so there is no reference data for withstand current value.

    ▼The following types are standardized
    K type 1 pair / 2PIN current introduction terminal
    K type 2 pair / current introduction terminal 4PIN
    Flange: NW/KF, ICF, JIS-VF, JIS-VG

    ▼Custom-made products are also available.
    We can also accept a combination of multiple different types of terminals, flange size changes, and mounting on special flanges.
    Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning request, please click here.

    The number of electrode 4
    Pairs of Thermocouple 2
    type K Thermocouple / cable termina
    Electric current / 1 pc. 20 A
    Total current/1 terminal Milli
    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    electrode Chromel ® / alumel ® / oxygen-
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VG 25
    A 90
    B 8
    D 45
    The contents of goods Assembled set
  • Product code :40933
    Model:G40TCK2WP4GA

    ▼ Thermocouple BURNDY K type 2 pairs + current induction terminal 4PIN
    Mates with bayonet locking plug
    K type (Chromel®Almel®) thermocouple terminals for temperature measurement
    Copper electrode: 20A compatible
    Power induction and thermal measurement in one port
    Easy connection by simply inserting along the guide groove even in difficult-to-see locations
    In addition to vacuum/atmosphere side connection parts and tools, we also offer pre-assembled products and assembly services (pre-assembled products: for vacuum side/For Atmospheric side)
    ※Thermocouple electrodes are designed for thermal measurement, so there is no reference data for withstand current value.

    ▼The following types are standardized
    K type 1 pair / 2PIN current introduction terminal
    K type 2 pair / current introduction terminal 4PIN
    Flange: NW/KF, ICF, JIS-VF, JIS-VG

    ▼Custom-made products are also available.
    We can also accept a combination of multiple different types of terminals, flange size changes, and mounting on special flanges.
    Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning request, please click here.

    The number of electrode 4
    Pairs of Thermocouple 2
    type K Thermocouple / cable termina
    Electric current / 1 pc. 20 A
    Total current/1 terminal Milli
    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    electrode Chromel ® / alumel ® / oxygen-
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VG 40
    A 105
    B 10
    D 47
    The contents of goods Only flanged terminal
  • Product code :40934
    Model:G40TCK2WP4GUT1B

    ▼ Thermocouple BURNDY K type 2 pairs + current induction terminal 4PIN
    Mates with bayonet locking plug
    K type (Chromel®Almel®) thermocouple terminals for temperature measurement
    Copper electrode: 20A compatible
    Power induction and thermal measurement in one port
    Easy connection by simply inserting along the guide groove even in difficult-to-see locations
    In addition to vacuum/atmosphere side connection parts and tools, we also offer pre-assembled products and assembly services (pre-assembled products: for vacuum side/For Atmospheric side)
    ※Thermocouple electrodes are designed for thermal measurement, so there is no reference data for withstand current value.

    ▼The following types are standardized
    K type 1 pair / 2PIN current introduction terminal
    K type 2 pair / current introduction terminal 4PIN
    Flange: NW/KF, ICF, JIS-VF, JIS-VG

    ▼Custom-made products are also available.
    We can also accept a combination of multiple different types of terminals, flange size changes, and mounting on special flanges.
    Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning request, please click here.

    The number of electrode 4
    Pairs of Thermocouple 2
    type K Thermocouple / cable termina
    Electric current / 1 pc. 20 A
    Total current/1 terminal Milli
    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    electrode Chromel ® / alumel ® / oxygen-
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VG 40
    A 105
    B 10
    D 47
    The contents of goods Assembled set
  • Product code :40935
    Model:G50TCK2WP4GA

    ▼ Thermocouple BURNDY K type 2 pairs + current induction terminal 4PIN
    Mates with bayonet locking plug
    K type (Chromel®Almel®) thermocouple terminals for temperature measurement
    Copper electrode: 20A compatible
    Power induction and thermal measurement in one port
    Easy connection by simply inserting along the guide groove even in difficult-to-see locations
    In addition to vacuum/atmosphere side connection parts and tools, we also offer pre-assembled products and assembly services (pre-assembled products: for vacuum side/For Atmospheric side)
    ※Thermocouple electrodes are designed for thermal measurement, so there is no reference data for withstand current value.

    ▼The following types are standardized
    K type 1 pair / 2PIN current introduction terminal
    K type 2 pair / current introduction terminal 4PIN
    Flange: NW/KF, ICF, JIS-VF, JIS-VG

    ▼Custom-made products are also available.
    We can also accept a combination of multiple different types of terminals, flange size changes, and mounting on special flanges.
    Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning request, please click here.

    The number of electrode 4
    Pairs of Thermocouple 2
    type K Thermocouple / cable termina
    Electric current / 1 pc. 20 A
    Total current/1 terminal Milli
    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    electrode Chromel ® / alumel ® / oxygen-
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VG 50
    A 120
    B 10
    D 47
    The contents of goods Only flanged terminal
  • Product code :40936
    Model:G50TCK2WP4GUT1B

    ▼ Thermocouple BURNDY K type 2 pairs + current induction terminal 4PIN
    Mates with bayonet locking plug
    K type (Chromel®Almel®) thermocouple terminals for temperature measurement
    Copper electrode: 20A compatible
    Power induction and thermal measurement in one port
    Easy connection by simply inserting along the guide groove even in difficult-to-see locations
    In addition to vacuum/atmosphere side connection parts and tools, we also offer pre-assembled products and assembly services (pre-assembled products: for vacuum side/For Atmospheric side)
    ※Thermocouple electrodes are designed for thermal measurement, so there is no reference data for withstand current value.

    ▼The following types are standardized
    K type 1 pair / 2PIN current introduction terminal
    K type 2 pair / current introduction terminal 4PIN
    Flange: NW/KF, ICF, JIS-VF, JIS-VG

    ▼Custom-made products are also available.
    We can also accept a combination of multiple different types of terminals, flange size changes, and mounting on special flanges.
    Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning request, please click here.

    The number of electrode 4
    Pairs of Thermocouple 2
    type K Thermocouple / cable termina
    Electric current / 1 pc. 20 A
    Total current/1 terminal Milli
    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    electrode Chromel ® / alumel ® / oxygen-
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VG 50
    A 120
    B 10
    D 47
    The contents of goods Assembled set
  • Product code :11396
    Model:N40MB42G

    ▼Multi-pin BURNDY® guided multiple terminals
    Hybrid feedthroughs combining multiple terminals
    Multiple terminals can be used for different applications.
    Terminals: Multi-pin high current type, K thermocouple, T thermocouple
    Separate power induction and thermal measurement on a single port.

    ▼Custom-made products are also available.
    Combination of multiple and different types of terminals, change of flange size, and mounting on special flanges are also available.
    Please contact us from the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 40
    type High current
    A 55
    B 41.2
    D1 38
    D2 38
    The contents of goods Only flanged terminal
    The number of electrode 8(4+4)
    Electric current / 1 pc. 10 A
    Total current/1 terminal 33.1 A
  • Product code :18927
    Model:N40MB42GUT1A

    ▼Multi-pin BURNDY® guided multiple terminals
    Hybrid feedthroughs combining multiple terminals
    Multiple terminals can be used for different applications.
    Terminals: Multi-pin high current type, K thermocouple, T thermocouple
    Separate power induction and thermal measurement on a single port.

    ▼Custom-made products are also available.
    Combination of multiple and different types of terminals, change of flange size, and mounting on special flanges are also available.
    Please contact us from the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 40
    type High current
    A 55
    B 41.2
    D1 38
    D2 38
    The contents of goods Assembled set
    The number of electrode 8(4+4)
    Electric current / 1 pc. 10 A
    Total current/1 terminal 33.1 A
  • Product code :11397
    Model:N40MB82G

    ▼Multi-pin BURNDY® guided multiple terminals
    Hybrid feedthroughs combining multiple terminals
    Multiple terminals can be used for different applications.
    Terminals: Multi-pin high current type, K thermocouple, T thermocouple
    Separate power induction and thermal measurement on a single port.

    ▼Custom-made products are also available.
    Combination of multiple and different types of terminals, change of flange size, and mounting on special flanges are also available.
    Please contact us from the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 40
    type High current
    A 55
    B 41.2
    D1 38
    D2 38
    The contents of goods Only flanged terminal
    The number of electrode 16(8+8)
    Electric current / 1 pc. 10 A
    Total current/1 terminal 33.1 A
  • Product code :18928
    Model:N40MB82GUT1A

    ▼Multi-pin BURNDY® guided multiple terminals
    Hybrid feedthroughs combining multiple terminals
    Multiple terminals can be used for different applications.
    Terminals: Multi-pin high current type, K thermocouple, T thermocouple
    Separate power induction and thermal measurement on a single port.

    ▼Custom-made products are also available.
    Combination of multiple and different types of terminals, change of flange size, and mounting on special flanges are also available.
    Please contact us from the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 40
    type High current
    A 55
    B 41.2
    D1 38
    D2 38
    The contents of goods Assembled set
    The number of electrode 16(8+8)
    Electric current / 1 pc. 10 A
    Total current/1 terminal 33.1 A
  • Product code :18908
    Model:N40MB842G

    ▼Multi-pin BURNDY® guided multiple terminals
    Hybrid feedthroughs combining multiple terminals
    Multiple terminals can be used for different applications.
    Terminals: Multi-pin high current type, K thermocouple, T thermocouple
    Separate power induction and thermal measurement on a single port.

    ▼Custom-made products are also available.
    Combination of multiple and different types of terminals, change of flange size, and mounting on special flanges are also available.
    Please contact us from the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 40
    type High current
    A 55
    B 41.2
    D1 38
    D2 38
    The contents of goods Only flanged terminal
    The number of electrode 12(8+4)
    Electric current / 1 pc. 10 A
    Total current/1 terminal 33.1 A
  • Product code :18930
    Model:N40MB842GUT1A

    ▼Multi-pin BURNDY® guided multiple terminals
    Hybrid feedthroughs combining multiple terminals
    Multiple terminals can be used for different applications.
    Terminals: Multi-pin high current type, K thermocouple, T thermocouple
    Separate power induction and thermal measurement on a single port.

    ▼Custom-made products are also available.
    Combination of multiple and different types of terminals, change of flange size, and mounting on special flanges are also available.
    Please contact us from the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 40
    type High current
    A 55
    B 41.2
    D1 38
    D2 38
    The contents of goods Assembled set
    The number of electrode 12(8+4)
    Electric current / 1 pc. 10 A
    Total current/1 terminal 33.1 A
  • Product code :18910
    Model:N40MB8TCK4G

    ▼Multi-pin BURNDY® guided multiple terminals
    Hybrid feedthroughs combining multiple terminals
    Multiple terminals can be used for different applications.
    Terminals: Multi-pin high current type, K thermocouple, T thermocouple
    Separate power induction and thermal measurement on a single port.

    ▼Custom-made products are also available.
    Combination of multiple and different types of terminals, change of flange size, and mounting on special flanges are also available.
    Please contact us from the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 40
    type K thermocouple/High current
    A 55
    B 41.2
    D1 38
    D2 38
    The contents of goods Only flanged terminal
    The number of electrode 8
    Pairs of Thermocouple 4
    Electric current / 1 pc. 10 A
    Total current/1 terminal 33.1 A
  • Product code :18932
    Model:N40MB8TCK4GUT1A

    ▼Multi-pin BURNDY® guided multiple terminals
    Hybrid feedthroughs combining multiple terminals
    Multiple terminals can be used for different applications.
    Terminals: Multi-pin high current type, K thermocouple, T thermocouple
    Separate power induction and thermal measurement on a single port.

    ▼Custom-made products are also available.
    Combination of multiple and different types of terminals, change of flange size, and mounting on special flanges are also available.
    Please contact us from the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 40
    type K thermocouple/High current
    A 55
    B 41.2
    D1 38
    D2 38
    The contents of goods Assembled set
    The number of electrode 8
    Pairs of Thermocouple 4
    Electric current / 1 pc. 10 A
    Total current/1 terminal 33.1 A
  • Product code :18912
    Model:N40MB8TCK2G

    ▼Multi-pin BURNDY® guided multiple terminals
    Hybrid feedthroughs combining multiple terminals
    Multiple terminals can be used for different applications.
    Terminals: Multi-pin high current type, K thermocouple, T thermocouple
    Separate power induction and thermal measurement on a single port.

    ▼Custom-made products are also available.
    Combination of multiple and different types of terminals, change of flange size, and mounting on special flanges are also available.
    Please contact us from the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 40
    type K thermocouple/High current
    A 55
    B 41.2
    D1 38
    D2 38
    The contents of goods Only flanged terminal
    The number of electrode 8
    Pairs of Thermocouple 2
    Electric current / 1 pc. 10 A
    Total current/1 terminal 33.1 A
  • Product code :18934
    Model:N40MB8TCK2GUT1A

    ▼Multi-pin BURNDY® guided multiple terminals
    Hybrid feedthroughs combining multiple terminals
    Multiple terminals can be used for different applications.
    Terminals: Multi-pin high current type, K thermocouple, T thermocouple
    Separate power induction and thermal measurement on a single port.

    ▼Custom-made products are also available.
    Combination of multiple and different types of terminals, change of flange size, and mounting on special flanges are also available.
    Please contact us from the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Withstand voltage: DC 500 V
    Insulation resistance value 10⁹ ohm
    frequency 10 MHz
    Connection type BURNDY
    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 40
    type K thermocouple/High current
    A 55
    B 41.2
    D1 38
    D2 38
    The contents of goods Assembled set
    The number of electrode 8
    Pairs of Thermocouple 2
    Electric current / 1 pc. 10 A
    Total current/1 terminal 33.1 A
Shipping accepted on the day on orders until 17:00 Hours 9:00 to 18:00 except Saturdays, Sundays, and holidays
Contact Us
Please fill in the form below.
After confirming the content of your enquiry,
a representative will contact you.

To use this service, please login or register as a member.

Not a member yet?

Registering as a member gives you access to a number of useful features.

ぜひご登録ください!

※ Please note that it may take several days after applying for a member registration until the registration is complete. Please note that we reserve the right to refuse your application at our discretion.