About 8,000 types of vacuum components in stock at all times.Business Hours: 9:00-18:00, excluding weekends and holidays

Product Category
  • Feedthrough Feedthrough
    Feedthrough
  • Isolator Isolator
    Isolator
  • Viewport Viewport
    Viewport
  • Vacuum Component Vacuum Component
    Vacuum Component
  • Vacuum Valve Vacuum Valve
    Vacuum Valve
  • Vented Screw Vented Screw
    Vented Screw
  • Others Others
    Others

Isolator Product List Isolator

Products 160Matter (21 ~40 )

Displayed results
Display switching
  • Product code :18680
    Model:TE59.5ISL24KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 59.5 mm
    Φ D1 70
    Φ D2 56
    Φ D3 58.5
    Φ D4 59.5
    L 92
    L1 40
    Withstand voltage: DC 24 kV
    sleeve Kovar ®
  • Product code :18681
    Model:TE80ISL12KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 80 mm
    Φ D1 100
    Φ D2 75
    Φ D3 76.5
    Φ D4 77.95
    L 85
    L1 20
    Withstand voltage: DC 12 kV
    sleeve Kovar ®
  • Product code :18682
    Model:TE80ISL24KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 80 mm
    Φ D1 100
    Φ D2 75
    Φ D3 76.5
    Φ D4 77.95
    L 105
    L1 40
    Withstand voltage: DC 24 kV
    sleeve Kovar ®
  • Product code :18683
    Model:TE103ISL12KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 103 mm
    Φ D1 148
    Φ D2 122
    Φ D3 101.5
    Φ D4 103
    L 95
    L1 20
    Withstand voltage: DC 12 kV
    sleeve Kovar ®
  • Product code :18684
    Model:TE103ISL24KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 103 mm
    Φ D1 148
    Φ D2 122
    Φ D3 101.5
    Φ D4 103
    L 115
    L1 40
    Withstand voltage: DC 24 kV
    sleeve Kovar ®
  • Product code :18685
    Model:TE138ISL12KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 138 mm
    Φ D1 190
    Φ D2 135
    Φ D3 136
    Φ D4 138
    L 100
    L1 20
    Withstand voltage: DC 12 kV
    sleeve Kovar ®
  • Product code :18686
    Model:TE138ISL24KV

    ▼ Insulation Fittings Tube End
    Withstand voltage: 1.8kV to 60kV
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Joint standard Tube end
    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Tube / Fitting Size 138 mm
    Φ D1 190
    Φ D2 135
    Φ D3 136
    Φ D4 138
    L 120
    L1 40
    Withstand voltage: DC 24 kV
    sleeve Kovar ®
  • Product code :18883
    Model:SW1/8ISL3KV

    ▼VCR® Insulated joints
    Withstand voltage: 1.8kV, 10kV
    VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Joint standard Swagelok®
    Tube / Fitting Size 1/8 inch
    L 100
    Withstand voltage: DC 3 kV
    sleeve 70-30 CuNi
  • Product code :13587
    Model:SW1/4ISL1KV

    ▼VCR® Insulated joints
    Withstand voltage: 1.8kV, 10kV
    VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Joint standard Swagelok®
    Tube / Fitting Size 1/4 inch
    L 103.2
    Withstand voltage: DC 1.8 kV
    sleeve Kovar ®
  • Product code :11812
    Model:SW1/4ISL10KV

    ▼VCR® Insulated joints
    Withstand voltage: 1.8kV, 10kV
    VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Joint standard Swagelok®
    Tube / Fitting Size 1/4 inch
    L 156.2
    Withstand voltage: DC 10 kV
    sleeve SUS 304
  • Product code :11939
    Model:SW1/2ISL10KV

    ▼VCR® Insulated joints
    Withstand voltage: 1.8kV, 10kV
    VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Joint standard Swagelok®
    Tube / Fitting Size 1/2 inch
    L 174.6
    Withstand voltage: DC 10 kV
    sleeve Kovar ®
  • Product code :18878
    Model:FM1/16ISL2KV

    ▼VCR® Insulated joints
    Withstand voltage: 1.8kV, 10kV
    VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Joint standard VCR® F-VCR® M
    Tube / Fitting Size 1/16 inch
    L 65
    Withstand voltage: DC 2 kV
    sleeve 70-30 CuNi
  • Product code :18882
    Model:FM1/8ISL3KV

    ▼VCR® Insulated joints
    Withstand voltage: 1.8kV, 10kV
    VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Joint standard VCR® F-VCR® M
    Tube / Fitting Size 1/8 inch
    L 78
    Withstand voltage: DC 3 kV
    sleeve 70-30 CuNi
  • Product code :13590
    Model:FM1/4ISL1KV

    ▼VCR® Insulated joints
    Withstand voltage: 1.8kV, 10kV
    VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Joint standard VCR® F-VCR® M
    Tube / Fitting Size 1/4 inch
    L 70.7
    Withstand voltage: DC 1.8 kV
    sleeve Kovar ®
  • Product code :11826
    Model:FM1/4ISL10KV

    ▼VCR® Insulated joints
    Withstand voltage: 1.8kV, 10kV
    VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Joint standard VCR® F-VCR® M
    Tube / Fitting Size 1/4 inch
    L 108.4
    Withstand voltage: DC 10 kV
    sleeve SUS 304
  • Product code :11837
    Model:FM1/2ISL10KV

    ▼VCR® Insulated joints
    Withstand voltage: 1.8kV, 10kV
    VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Joint standard VCR® F-VCR® M
    Tube / Fitting Size 1/2 inch
    L 118.5
    Withstand voltage: DC 10 kV
    sleeve Kovar ®
  • Product code :18876
    Model:FVCR1/16ISL2KV

    ▼VCR® Insulated joints
    Withstand voltage: 1.8kV, 10kV
    VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Joint standard VCR® F
    Tube / Fitting Size 1/16 inch
    L 65
    Withstand voltage: DC 2 kV
    sleeve 70-30 CuNi
  • Product code :18880
    Model:FVCR1/8ISL3KV

    ▼VCR® Insulated joints
    Withstand voltage: 1.8kV, 10kV
    VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Joint standard VCR® F
    Tube / Fitting Size 1/8 inch
    L 78
    Withstand voltage: DC 3 kV
    sleeve 70-30 CuNi
  • Product code :13588
    Model:FVCR1/4ISL1KV

    ▼VCR® Insulated joints
    Withstand voltage: 1.8kV, 10kV
    VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Joint standard VCR® F
    Tube / Fitting Size 1/4 inch
    L 55.4
    Withstand voltage: DC 1.8 kV
    sleeve Kovar ®
  • Product code :11898
    Model:FVCR1/4ISL10KV

    ▼VCR® Insulated joints
    Withstand voltage: 1.8kV, 10kV
    VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Joint standard VCR® F
    Tube / Fitting Size 1/4 inch
    L 108.4
    Withstand voltage: DC 10 kV
    sleeve SUS 304
Shipping accepted on the day on orders until 17:00 Hours 9:00 to 18:00 except Saturdays, Sundays, and holidays
Contact Us
Please fill in the form below.
After confirming the content of your enquiry,
a representative will contact you.

To use this service, please login or register as a member.

Not a member yet?

Registering as a member gives you access to a number of useful features.

ぜひご登録ください!

※ Please note that it may take several days after applying for a member registration until the registration is complete. Please note that we reserve the right to refuse your application at our discretion.