type | OMEGA™ Thermocouple C Type |
---|---|
Total current/1 terminal | Milli |
Withstand voltage: DC | Milli |
Connection type | OMEGA™ |
electrode | Tungsten-rhenium alloys |
Flange material | SUS 304 |
sleeve | SUS 304 |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -100℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
type | OMEGA™ Thermocouple E Type |
---|---|
Total current/1 terminal | Milli |
Withstand voltage: DC | Milli |
Connection type | OMEGA™ |
electrode | Clomel® / Constantan® |
Flange material | SUS 304 |
sleeve | SUS 304 |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -100℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
type | MS |
---|---|
Total current/1 terminal | Milli |
Withstand voltage: DC | Milli |
Connection type | MS |
electrode | Clomel® / Constantan® |
Flange material | SUS 304 |
sleeve | SUS 304 |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -100℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
type | OMEGA™ Thermocouple J Type |
---|---|
Total current/1 terminal | Milli |
Withstand voltage: DC | Milli |
Connection type | OMEGA™ |
electrode | Iron / Constantan® |
Flange material | SUS 304 |
sleeve | SUS 304 |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -100℃ |
type | MS |
---|---|
Total current/1 terminal | Milli |
Withstand voltage: DC | Milli |
Connection type | MS |
electrode | Iron / Constantan® |
Flange material | SUS 304 |
sleeve | SUS 304 |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -100℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
type | Thermocouple N Type |
---|---|
Total current/1 terminal | Milli |
Withstand voltage: DC | Milli |
electrode | Nike Rosil / Nike Rosil |
Flange material | SUS 304 |
sleeve | SUS 304 |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -100℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
type | Thermocouple R/S Type |
---|---|
Total current/1 terminal | Milli |
Withstand voltage: DC | Milli |
Electrode* | OFHC / Al-Ni-Co alloy |
Flange material | SUS 304 |
sleeve | SUS 304 |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -100℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
type | BNC |
---|---|
Connection type | For the air-side plug-fitting |
Flange material | SUS 304 |
Classification | Flanged terminal |
Impedance | non-contact |
Withstand voltage: DC | 500 V |
type | BNC |
---|---|
Connection type | The atmosphere-side plug-fitti |
Flange material | SUS 304 |
Impedance | non-contact |
Withstand voltage: DC | 500 V |
type | High Voltage RF |
---|---|
electrode | Oxygen-free copper |
Flange material | SUS 304 |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -100℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Withstand voltage: DC | 8 kV |
Electric current / 1 pc. | N/A |
Feedthrough | 8 kV |
type | High Voltage RF |
---|---|
electrode | Oxygen-free copper |
Flange material | SUS 304 |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -100℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Withstand voltage: DC | 10 kV |
Electric current / 1 pc. | N/A |
Feedthrough | 10 kV |
type | High voltage and low current |
---|---|
electrode | stainless steel |
Flange material | SUS 304 |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -100℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Withstand voltage: DC | 25 kV |
Electric current / 1 pc. | 3 A |
Feedthrough | 25 kV / 3 A |
type | High-voltage and medium curren |
---|---|
electrode | Oxygen-free copper |
Flange material | SUS 304 |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -100℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
Withstand voltage: DC | 30 kV |
Electric current / 1 pc. | 50 A |
Feedthrough | 30 kV / 50 A |
The number of terminals | 1 |
---|---|
type | standard |
Withstand voltage: DC | 500 V |
Insulation resistance value | 10⁹ ohm |
frequency | 10 MHz |
Connection type | BURNDY |
electrode | Kovar ® |
Flange material | SUS 304 |
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
The number of terminals | 1 |
---|---|
type | standard |
Withstand voltage: DC | 500 V |
Insulation resistance value | 10⁹ ohm |
frequency | 10 MHz |
Connection type | MS(MIL-C5015) |
electrode | Kovar ® |
Flange material | SUS 304 |
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
The number of terminals | 1 |
---|---|
type | Thermocouple type K |
Withstand voltage: DC | Milli |
Insulation resistance value | 10⁹ ohm |
frequency | 10 MHz |
Connection type | BURNDY |
electrode | Chromel ® / alumel ® |
Flange material | SUS 304 |
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 450℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |