About 8,000 types of vacuum components in stock at all times.Business Hours: 9:00-18:00, excluding weekends and holidays

Product Category
  • Feedthrough Feedthrough
    Feedthrough
  • Isolator Isolator
    Isolator
  • Viewport Viewport
    Viewport
  • Vacuum Component Vacuum Component
    Vacuum Component
  • Vacuum Valve Vacuum Valve
    Vacuum Valve
  • Vented Screw Vented Screw
    Vented Screw
  • Others Others
    Others

ICF Standard Product List Isolator

Products 32Matter (21 ~32 )

Displayed results
Display switching
  • Product code :12150
    Model:C34ISL6KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 34
    Φ D1 25
    Φ D2 14
    Φ D3 15.4
    Φ D4 14
    Φ D5 34
    Φ D6 26
    Φ D7 12
    L2 10
    L3 63 ~ 71
    T1 7.5
    T2 7.5
    Withstand voltage: DC 6 kV
  • Product code :12144
    Model:C34ISL12KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 34
    Φ D1 25
    Φ D2 14
    Φ D3 15.4
    Φ D4 14
    Φ D5 34
    Φ D6 26
    Φ D7 12
    L2 20
    L3 71 ~ 79
    T1 7.5
    T2 7.5
    Withstand voltage: DC 12 kV
  • Product code :10314
    Model:C70ISL12KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 70
    Φ D1 42
    Φ D2 27
    Φ D3 29
    Φ D4 31
    Φ D5 70
    Φ D6 40
    Φ D7 27
    L2 20
    L3 88.5 ~ 96.5
    T1 12.7
    T2 12.7
    Withstand voltage: DC 12 kV
  • Product code :10313
    Model:C70ISL24KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 70
    Φ D1 42
    Φ D2 27
    Φ D3 29
    Φ D4 31
    Φ D5 70
    Φ D6 40
    Φ D7 27
    L2 40
    L3 108.5 ~ 116.5
    T1 12.7
    T2 12.7
    Withstand voltage: DC 24 kV
  • Product code :10306
    Model:C114ISL12KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 114
    Φ D1 70
    Φ D2 56
    Φ D3 58.5
    Φ D4 60.5
    Φ D5 114
    Φ D6 80
    Φ D7 60
    L2 20
    L3 100.5 ~ 108.5
    T1 19
    T2 17.5
    Withstand voltage: DC 12 kV
  • Product code :10324
    Model:C114ISL24KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 114
    Φ D1 70
    Φ D2 56
    Φ D3 58.5
    Φ D4 60.5
    Φ D5 114
    Φ D6 80
    Φ D7 60
    L2 40
    L3 120.5 ~ 128.5
    T1 19
    T2 17.5
    Withstand voltage: DC 24 kV
  • Product code :10323
    Model:C152ISL12KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 152
    Φ D1 100
    Φ D2 75
    Φ D3 76.5
    Φ D4 79.5
    Φ D5 152
    Φ D6 100
    Φ D7 75
    L2 20
    L3 105.5 ~ 113.5
    T1 21
    T2 20
    Withstand voltage: DC 12 kV
  • Product code :12145
    Model:C152ISL24KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 152
    Φ D1 100
    Φ D2 75
    Φ D3 76.5
    Φ D4 79.5
    Φ D5 152
    Φ D6 100
    Φ D7 75
    L2 40
    L3 125.5 ~ 133.5
    T1 21
    T2 20
    Withstand voltage: DC 24 kV
  • Product code :12146
    Model:C203ISL12KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 203
    Φ D1 148
    Φ D2 122
    Φ D3 101.5
    Φ D4 104.5
    Φ D5 203
    Φ D6 162
    Φ D7 132
    L2 20
    L3 118 ~ 126
    T1 24
    T2 22
    Withstand voltage: DC 12 kV
  • Product code :12147
    Model:C203ISL24KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 203
    Φ D1 148
    Φ D2 122
    Φ D3 101.5
    Φ D4 104.5
    Φ D5 203
    Φ D6 162
    Φ D7 132
    L2 40
    L3 138 ~ 147
    T1 24
    T2 22
    Withstand voltage: DC 24 kV
  • Product code :12148
    Model:C253ISL12KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 253
    Φ D1 190
    Φ D2 135
    Φ D3 136
    Φ D4 140
    Φ D5 253
    Φ D6 185
    Φ D7 135
    L2 20
    L3 117 ~ 125
    T1 25
    T2 25
    Withstand voltage: DC 12 kV
  • Product code :12149
    Model:C253ISL24KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 253
    Φ D1 190
    Φ D2 135
    Φ D3 136
    Φ D4 140
    Φ D5 253
    Φ D6 185
    Φ D7 135
    L2 40
    L3 137 ~ 145
    T1 25
    T2 25
    Withstand voltage: DC 24 kV
Shipping accepted on the day on orders until 17:00 Hours 9:00 to 18:00 except Saturdays, Sundays, and holidays
Contact Us
Please fill in the form below.
After confirming the content of your enquiry,
a representative will contact you.

To use this service, please login or register as a member.

Not a member yet?

Registering as a member gives you access to a number of useful features.

ぜひご登録ください!

※ Please note that it may take several days after applying for a member registration until the registration is complete. Please note that we reserve the right to refuse your application at our discretion.