About 8,000 types of vacuum components in stock at all times.Business Hours: 9:00-18:00, excluding weekends and holidays

Product Category
  • Feedthrough Feedthrough
    Feedthrough
  • Isolator Isolator
    Isolator
  • Viewport Viewport
    Viewport
  • Vacuum Component Vacuum Component
    Vacuum Component
  • Vacuum Valve Vacuum Valve
    Vacuum Valve
  • Vented Screw Vented Screw
    Vented Screw
  • Others Others
    Others
  1. Cosmotec for Vacuum Components
  2. Feedthrough
  3. High-voltage
  4. Feedthrough high-voltage and high current 10kV-22A ~ 808A

Feedthrough high-voltage and high current 10kV-22A ~ 808A Product List Feedthrough

Products 91Matter (41 ~60 )

Displayed results
Display switching
  • Product code :11372
    Model:F510K476ACU1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4
    Four SUS nuts (M16) for connection are included per electrode

    ▼The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    VF 50
    A 120
    B 10
    C 25
    D 80
    The number of terminals 1
    type High voltage and high current
    Feedthrough 10 kV / 476 A
    Electric current / 1 pc. 476 A
    electrode Oxygen-free copper
    62,900JPY (with tax 69,190JPY)
    Inquiry for this product
  • Product code :11376
    Model:F510K73ASS1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4
    Four SUS nuts (M16) for connection are included per electrode

    ▼The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    VF 50
    A 120
    B 10
    C 25
    D 80
    The number of terminals 1
    type High-voltage and medium curren
    Feedthrough 10 kV / 73 A
    Electric current / 1 pc. 73 A
    electrode SUS 304
    73,600JPY (with tax 80,960JPY)
    Inquiry for this product
  • Product code :11423
    Model:G310K476ACU1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4
    Four SUS nuts (M16) for connection are included per electrode

    ▼The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    VG 25
    A 90
    B 8
    C 25
    D 80
    The number of terminals 1
    type High voltage and high current
    Feedthrough 10 kV / 476 A
    Electric current / 1 pc. 476 A
    electrode Oxygen-free copper
    60,700JPY (with tax 66,770JPY)
    Inquiry for this product
  • Product code :11426
    Model:G310K73ASS1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4
    Four SUS nuts (M16) for connection are included per electrode

    ▼The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    VG 25
    A 90
    B 8
    C 25
    D 80
    The number of terminals 1
    type High-voltage and medium curren
    Feedthrough 10 kV / 73 A
    Electric current / 1 pc. 73 A
    electrode SUS 304
    71,400JPY (with tax 78,540JPY)
    Inquiry for this product
  • Product code :11451
    Model:G410K476ACU1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4
    Four SUS nuts (M16) for connection are included per electrode

    ▼The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    VG 40
    A 105
    B 10
    C 25
    D 80
    The number of terminals 1
    type High voltage and high current
    Feedthrough 10 kV / 476 A
    Electric current / 1 pc. 476 A
    electrode Oxygen-free copper
    61,700JPY (with tax 67,870JPY)
    Inquiry for this product
  • Product code :11455
    Model:G410K73ASS1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4
    Four SUS nuts (M16) for connection are included per electrode

    ▼The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    VG 40
    A 105
    B 10
    C 25
    D 80
    The number of terminals 1
    type High-voltage and medium curren
    Feedthrough 10 kV / 73 A
    Electric current / 1 pc. 73 A
    electrode SUS 304
    72,400JPY (with tax 79,640JPY)
    Inquiry for this product
  • Product code :11485
    Model:G510K476ACU1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4
    Four SUS nuts (M16) for connection are included per electrode

    ▼The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    VG 50
    A 120
    B 10
    C 25
    D 80
    The number of terminals 1
    type High voltage and high current
    Feedthrough 10 kV / 476 A
    Electric current / 1 pc. 476 A
    electrode Oxygen-free copper
    62,900JPY (with tax 69,190JPY)
    Inquiry for this product
  • Product code :11489
    Model:G510K73ASS1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4
    Four SUS nuts (M16) for connection are included per electrode

    ▼The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    VG 50
    A 120
    B 10
    C 25
    D 80
    The number of terminals 1
    type High-voltage and medium curren
    Feedthrough 10 kV / 73 A
    Electric current / 1 pc. 73 A
    electrode SUS 304
    73,600JPY (with tax 80,960JPY)
    Inquiry for this product
  • Product code :11559
    Model:N510K808ACU1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4

    ▼ The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    NW/KF 50
    A 75
    B 6
    C 22.5
    D 82.5
    The number of terminals 1
    type High voltage and high current
    Feedthrough 10 kV / 808 A
    Electric current / 1 pc. 808 A
    electrode Oxygen-free copper
    74,300JPY (with tax 81,730JPY)
    Inquiry for this product
  • Product code :11558
    Model:N510K124ASS1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4

    ▼ The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    NW/KF 50
    A 75
    B 6
    C 22.5
    D 82.5
    The number of terminals 1
    type High voltage and high current
    Feedthrough 10 kV / 124 A
    Electric current / 1 pc. 124 A
    electrode SUS 304
    74,300JPY (with tax 81,730JPY)
    Inquiry for this product
  • Product code :11262
    Model:C310K808ACU1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4

    ▼ The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    ICF 114
    A 114
    B 17.5
    C 23
    D 82
    The number of terminals 1
    type High voltage and high current
    Feedthrough 10 kV / 808 A
    Electric current / 1 pc. 808 A
    electrode Oxygen-free copper
    81,500JPY (with tax 89,650JPY)
    Inquiry for this product
  • Product code :11261
    Model:C310K124ASS1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4

    ▼ The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    ICF 114
    A 114
    B 17.5
    C 23
    D 82
    The number of terminals 1
    type High voltage and high current
    Feedthrough 10 kV / 124 A
    Electric current / 1 pc. 124 A
    electrode SUS 304
    81,500JPY (with tax 89,650JPY)
    Inquiry for this product
  • Product code :11343
    Model:F410K808ACU1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4

    ▼ The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    VF 40
    A 105
    B 10
    C 25
    D 80
    The number of terminals 1
    type High voltage and high current
    Feedthrough 10 kV / 808 A
    Electric current / 1 pc. 808 A
    electrode Oxygen-free copper
    77,100JPY (with tax 84,810JPY)
    Inquiry for this product
  • Product code :11339
    Model:F410K124ASS1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4

    ▼ The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    VF 40
    A 105
    B 10
    C 25
    D 80
    The number of terminals 1
    type High voltage and high current
    Feedthrough 10 kV / 124 A
    Electric current / 1 pc. 124 A
    electrode SUS 304
    77,100JPY (with tax 84,810JPY)
    Inquiry for this product
  • Product code :11377
    Model:F510K808ACU1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4

    ▼ The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    VF 50
    A 120
    B 10
    C 25
    D 80
    The number of terminals 1
    type High voltage and high current
    Feedthrough 10 kV / 808 A
    Electric current / 1 pc. 808 A
    electrode Oxygen-free copper
    78,300JPY (with tax 86,130JPY)
    Inquiry for this product
  • Product code :11373
    Model:F510K124ASS1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4

    ▼ The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    VF 50
    A 120
    B 10
    C 25
    D 80
    The number of terminals 1
    type High voltage and high current
    Feedthrough 10 kV / 124 A
    Electric current / 1 pc. 124 A
    electrode SUS 304
    78,300JPY (with tax 86,130JPY)
    Inquiry for this product
  • Product code :11456
    Model:G410K808ACU1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4

    ▼ The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    VG 40
    A 105
    B 10
    C 25
    D 80
    The number of terminals 1
    type High voltage and high current
    Feedthrough 10 kV / 808 A
    Electric current / 1 pc. 808 A
    electrode Oxygen-free copper
    77,100JPY (with tax 84,810JPY)
    Inquiry for this product
  • Product code :11452
    Model:G410K124ASS1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4

    ▼ The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    VG 40
    A 105
    B 10
    C 25
    D 80
    The number of terminals 1
    type High voltage and high current
    Feedthrough 10 kV / 124 A
    Electric current / 1 pc. 124 A
    electrode SUS 304
    77,100JPY (with tax 84,810JPY)
    Inquiry for this product
  • Product code :11490
    Model:G510K808ACU1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4

    ▼ The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    VG 50
    A 120
    B 10
    C 25
    D 80
    The number of terminals 1
    type High voltage and high current
    Feedthrough 10 kV / 808 A
    Electric current / 1 pc. 808 A
    electrode Oxygen-free copper
    78,300JPY (with tax 86,130JPY)
    Inquiry for this product
  • Product code :11486
    Model:G510K124ASS1

    ▼ High voltage feedthroughs
    Used in applications such as power, heaters, lamps, etc.
    With threaded tip for convenient connection
    Voltage 3kV to 30kV DC, current 3A to 808A
    Standardized electrode materials: oxygen-free copper, oxygen-free copper + nickel plating, and stainless steel
    Number of electrodes: 1, 2, 3, 4

    ▼ The following types are standardized (list)
    Electrode with threading: Oxygen-free copper, Oxygen-free copper + Nickel plating, SUS
    Compact type (without electrode threading): Oxygen-free copper (5kV 22A), SUS (5kV 3A)
    Silicon plug type: Oxygen-free copper (3kV 35A, 5kV 110A)
    Flange: NW/KF, ICF, JIS-VF, JIS-VG
    Protective cover for voltage terminals corresponding to ICF70 is also available.

    ▼ Custom-made products are also available.
    We can quickly respond to changes in terminal arrangement, quantity changes, flange standard size changes, welding of multiple products, and custom-ordered products. Please contact us by clicking the "Inquiry" button on the right side of this page.

    For precision cleaning requests, please click here.

    Flange material SUS 304
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 450℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    Insulation resistance value 10⁹ ohm
    Withstand voltage: DC 10 kV
    The number of electrode 1
    VG 50
    A 120
    B 10
    C 25
    D 80
    The number of terminals 1
    type High voltage and high current
    Feedthrough 10 kV / 124 A
    Electric current / 1 pc. 124 A
    electrode SUS 304
    78,300JPY (with tax 86,130JPY)
    Inquiry for this product
Shipping accepted on the day on orders until 17:00 Hours 9:00 to 18:00 except Saturdays, Sundays, and holidays
Contact Us
Please fill in the form below.
After confirming the content of your enquiry,
a representative will contact you.

To use this service, please login or register as a member.

Not a member yet?

Registering as a member gives you access to a number of useful features.

ぜひご登録ください!

※ Please note that it may take several days after applying for a member registration until the registration is complete. Please note that we reserve the right to refuse your application at our discretion.