Products 203Matter (161 ~180 )

Displayed results
Display switching
  • Product code :23582
    Model:VG50GP1/2BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 50
    Connection diameter (φ) 1/2 inch
    A 120
    B 22.2
    E 13
    L 34
  • Product code :23583
    Model:VG50GP3/4BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 50
    Connection diameter (φ) 3/4 inch
    A 120
    B 34.9
    E 19.4
    L 42
  • Product code :23584
    Model:VG50GP1/1BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 50
    Connection diameter (φ) 1/1 inch
    A 120
    B 41.3
    E 25.8
    L 48
  • Product code :27247
    Model:VG20GP2BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 20
    Connection diameter (φ) 2 mm
    A 80
    B 12
    E 2.5
    L 27
  • Product code :27248
    Model:VG20GP3BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 20
    Connection diameter (φ) 3 mm
    A 80
    B 14
    E 3.2
    L 37
  • Product code :27249
    Model:VG20GP4BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 20
    Connection diameter (φ) 4 mm
    A 80
    B 15
    E 4.5
    L 37
  • Product code :27250
    Model:VG20GP5BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 20
    Connection diameter (φ) 5 mm
    A 80
    B 15
    E 5.2
    L 42
  • Product code :27251
    Model:VG20GP6BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 20
    Connection diameter (φ) 6 mm
    A 80
    B 18
    E 6.3
    L 42
  • Product code :27252
    Model:VG20GP8BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 20
    Connection diameter (φ) 8 mm
    A 80
    B 19
    E 8.3
    L 41
  • Product code :27253
    Model:VG20GP10BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 20
    Connection diameter (φ) 10 mm
    A 80
    B 23
    E 10.3
    L 52
  • Product code :27254
    Model:VG20GP12BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 20
    Connection diameter (φ) 12 mm
    A 80
    B 25
    E 12.3
    L 52
  • Product code :27257
    Model:VG25GP2BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 25
    Connection diameter (φ) 2 mm
    A 90
    B 12
    E 2.5
    L 27
  • Product code :27258
    Model:VG25GP3BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 25
    Connection diameter (φ) 3 mm
    A 90
    B 14
    E 3.2
    L 37
  • Product code :27259
    Model:VG25GP4BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 25
    Connection diameter (φ) 4 mm
    A 90
    B 15
    E 4.5
    L 37
  • Product code :27260
    Model:VG25GP5BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 25
    Connection diameter (φ) 5 mm
    A 90
    B 15
    E 5.2
    L 42
  • Product code :27261
    Model:VG25GP6BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 25
    Connection diameter (φ) 6 mm
    A 90
    B 18
    E 6.3
    L 42
  • Product code :27262
    Model:VG25GP8BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 25
    Connection diameter (φ) 8 mm
    A 90
    B 19
    E 8.3
    L 41
  • Product code :27263
    Model:VG25GP10BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 25
    Connection diameter (φ) 10 mm
    A 90
    B 23
    E 10.3
    L 52
  • Product code :27264
    Model:VG25GP12BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 25
    Connection diameter (φ) 12 mm
    A 90
    B 25
    E 12.3
    L 52
  • Product code :27267
    Model:VG40GP2BT

    ▼JIS-VG Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VG 40
    Connection diameter (φ) 2 mm
    A 105
    B 12
    E 2.5
    L 27
Shipping accepted on the day on orders until 17:00 Hours 9:00 to 18:00 except Saturdays, Sundays, and holidays
Contact Us
Please fill in the form below.
After confirming the content of your enquiry,
a representative will contact you.

To use this service, please login or register as a member.

Not a member yet?

Registering as a member gives you access to a number of useful features.

ぜひご登録ください!

※ Please note that it may take several days after applying for a member registration until the registration is complete. Please note that we reserve the right to refuse your application at our discretion.