About 8,000 types of vacuum components in stock at all times.Business Hours: 9:00-18:00, excluding weekends and holidays

Product Category
  • Feedthrough Feedthrough
    Feedthrough
  • Isolator Isolator
    Isolator
  • Viewport Viewport
    Viewport
  • Vacuum Component Vacuum Component
    Vacuum Component
  • Vacuum Valve Vacuum Valve
    Vacuum Valve
  • Vented Screw Vented Screw
    Vented Screw
  • Others Others
    Others

Vacuum Piping Parts Gauge Port/Wilson Seal Product List Vacuum Component

Products 203Matter (121 ~140 )

Displayed results
Display switching
  • Product code :27211
    Model:VF20GP6BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 20
    Connection diameter (φ) 6 mm
    A 80
    B 18
    E 6.3
    L 42
  • Product code :27221
    Model:VF25GP6BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 25
    Connection diameter (φ) 6 mm
    A 90
    B 18
    E 6.3
    L 42
  • Product code :27231
    Model:VF40GP6BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 40
    Connection diameter (φ) 6 mm
    A 105
    B 18
    E 6.3
    L 42
  • Product code :27241
    Model:VF50GP6BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 50
    Connection diameter (φ) 6 mm
    A 120
    B 18
    E 6.3
    L 42
  • Product code :27212
    Model:VF20GP8BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 20
    Connection diameter (φ) 8 mm
    A 80
    B 19
    E 8.3
    L 41
  • Product code :27222
    Model:VF25GP8BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 25
    Connection diameter (φ) 8 mm
    A 90
    B 19
    E 8.3
    L 41
  • Product code :27232
    Model:VF40GP8BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 40
    Connection diameter (φ) 8 mm
    A 105
    B 19
    E 8.3
    L 41
  • Product code :27242
    Model:VF50GP8BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 50
    Connection diameter (φ) 8 mm
    A 120
    B 19
    E 8.3
    L 41
  • Product code :27213
    Model:VF20GP10BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 20
    Connection diameter (φ) 10 mm
    A 80
    B 23
    E 10.3
    L 52
  • Product code :27223
    Model:VF25GP10BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 25
    Connection diameter (φ) 10 mm
    A 90
    B 23
    E 10.3
    L 52
  • Product code :27233
    Model:VF40GP10BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 40
    Connection diameter (φ) 10 mm
    A 105
    B 23
    E 10.3
    L 52
  • Product code :27243
    Model:VF50GP10BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 50
    Connection diameter (φ) 10 mm
    A 120
    B 23
    E 10.3
    L 52
  • Product code :27214
    Model:VF20GP12BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 20
    Connection diameter (φ) 12 mm
    A 80
    B 25
    E 12.3
    L 52
  • Product code :27224
    Model:VF25GP12BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 25
    Connection diameter (φ) 12 mm
    A 90
    B 25
    E 12.3
    L 52
  • Product code :27234
    Model:VF40GP12BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 40
    Connection diameter (φ) 12 mm
    A 105
    B 25
    E 12.3
    L 52
  • Product code :27244
    Model:VF50GP12BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 50
    Connection diameter (φ) 12 mm
    A 120
    B 25
    E 12.3
    L 52
  • Product code :27215
    Model:VF20GP15BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 20
    Connection diameter (φ) 15 mm
    A 80
    B 40
    E 16
    L 56
  • Product code :27225
    Model:VF25GP15BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 25
    Connection diameter (φ) 15 mm
    A 90
    B 40
    E 16
    L 56
  • Product code :27235
    Model:VF40GP15BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 40
    Connection diameter (φ) 15 mm
    A 105
    B 40
    E 16
    L 56
  • Product code :27245
    Model:VF50GP15BT

    ▼JIS-VF Gauge port
    Used to introduce a vacuum gauge, tubing, etc.
    O-ring sealed inside the port
    Step type: Tubes, etc. inserted into the port are not pulled in when a vacuum is pulled out.
    Bored-through type: No step inside. Select this type when you want to introduce tubes, etc. to the inside of the chamber.
    No vacuum grease is required.
    Flange size (JIS):20,25,40,50

    ▼About sheathed thermocouples
    Bored-through type can be used for sheathed thermocouples.
    For φ3.2 sheath = 1/8 inch
    For φ6.4 sheath = 1/4 inch

    ▼The following types are standardized (List)
    Hole diameter (inch): 1/8, 1/4, 3/8, 1/2, 3/4, 1, 1-1/4, 1-1/2, 2
    Hole diameter (mm): 2, 3, 4, 5, 6, 8, 10, 12, 15, 18
    Flange: ICF, NW/KF, JIS-VF, JIS-VG
    *Gauge port stand-alone is here.

    ▼Options
    Sealing plugs are also available while not used as ports.
    We can also change the number of ports and flange size. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    Seal / gasket material Viton ®
    body SUS 304
    RoHS2 corresponding
    VF 50
    Connection diameter (φ) 15 mm
    A 120
    B 40
    E 16
    L 56
Shipping accepted on the day on orders until 17:00 Hours 9:00 to 18:00 except Saturdays, Sundays, and holidays
Contact Us
Please fill in the form below.
After confirming the content of your enquiry,
a representative will contact you.

To use this service, please login or register as a member.

Not a member yet?

Registering as a member gives you access to a number of useful features.

ぜひご登録ください!

※ Please note that it may take several days after applying for a member registration until the registration is complete. Please note that we reserve the right to refuse your application at our discretion.