About 8,000 types of vacuum components in stock at all times.Business Hours: 9:00-18:00, excluding weekends and holidays
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
Attachment port of the vacuum gauge, has been used in the exhaust connection port and the like.
Up to ICF 34 ~ ICF 253 will have been standardized.
1 direction of the three directions stocks conversion tea of different flange size as a standard product.
It changes and the like of various dimensions, quickly can also be accommodated with respect to special order.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 34 |
A | 34 |
C | 19.1 |
D | 15.7 |
L | 37.5 |
Attachment port of the vacuum gauge, has been used in the exhaust connection port and the like.
Up to ICF 34 ~ ICF 253 will have been standardized.
1 direction of the three directions stocks conversion tea of different flange size as a standard product.
It changes and the like of various dimensions, quickly can also be accommodated with respect to special order.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 70 |
A | 70 |
C | 38 |
D | 35 |
L | 54.2 |
Attachment port of the vacuum gauge, has been used in the exhaust connection port and the like.
Up to ICF 34 ~ ICF 253 will have been standardized.
1 direction of the three directions stocks conversion tea of different flange size as a standard product.
It changes and the like of various dimensions, quickly can also be accommodated with respect to special order.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 114 |
A | 114 |
C | 63.5 |
D | 60.2 |
L | 93 |
Attachment port of the vacuum gauge, has been used in the exhaust connection port and the like.
Up to ICF 34 ~ ICF 253 will have been standardized.
1 direction of the three directions stocks conversion tea of different flange size as a standard product.
It changes and the like of various dimensions, quickly can also be accommodated with respect to special order.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 152 |
A | 152 |
C | 101.6 |
D | 97.6 |
L | 109.5 |
Attachment port of the vacuum gauge, has been used in the exhaust connection port and the like.
Up to ICF 34 ~ ICF 253 will have been standardized.
1 direction of the three directions stocks conversion tea of different flange size as a standard product.
It changes and the like of various dimensions, quickly can also be accommodated with respect to special order.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 203 |
A | 203 |
C | 153 |
D | 147 |
L | 139.7 |
Attachment port of the vacuum gauge, has been used in the exhaust connection port and the like.
Up to ICF 34 ~ ICF 253 will have been standardized.
1 direction of the three directions stocks conversion tea of different flange size as a standard product.
It changes and the like of various dimensions, quickly can also be accommodated with respect to special order.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 253 |
A | 253 |
C | 203 |
D | 197 |
L | 203 |
Attachment port of the vacuum gauge, has been used in the exhaust connection port and the like.
Up to ICF 34 ~ ICF 253 will have been standardized.
1 direction of the three directions stocks conversion tea of ??different flange size as a standard product.
It changes and the like of various dimensions, quickly can also be accommodated with respect to special order.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 70 |
ICF | 34 |
A | 70 |
B | 34 |
C | 42.7 |
D | 39.4 |
C1 | 19.05 |
D1 | 15.75 |
L1 | 48 |
L2 | 63 |
Attachment port of the vacuum gauge, has been used in the exhaust connection port and the like.
Up to ICF 34 ~ ICF 253 will have been standardized.
1 direction of the three directions stocks conversion tea of ??different flange size as a standard product.
It changes and the like of various dimensions, quickly can also be accommodated with respect to special order.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 114 |
ICF | 34 |
A | 114 |
B | 34 |
C | 63.5 |
C1 | 19.05 |
D | 59.5 |
D1 | 15.75 |
L1 | 75 |
L2 | 85 |
Attachment port of the vacuum gauge, has been used in the exhaust connection port and the like.
Up to ICF 34 ~ ICF 253 will have been standardized.
1 direction of the three directions stocks conversion tea of ??different flange size as a standard product.
It changes and the like of various dimensions, quickly can also be accommodated with respect to special order.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 114 |
ICF | 70 |
A | 114 |
B | 70 |
C | 63.5 |
C1 | 42.7 |
D | 59.5 |
D1 | 39.4 |
L1 | 75 |
L2 | 85 |
Attachment port of the vacuum gauge, has been used in the exhaust connection port and the like.
Up to ICF 34 ~ ICF 253 will have been standardized.
1 direction of the three directions stocks conversion tea of ??different flange size as a standard product.
It changes and the like of various dimensions, quickly can also be accommodated with respect to special order.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 152 |
ICF | 70 |
A | 152 |
B | 70 |
C | 101.6 |
C1 | 42.7 |
D | 97.4 |
D1 | 39.4 |
L1 | 105 |
L2 | 110 |
Attachment port of the vacuum gauge, has been used in the exhaust connection port and the like.
Up to ICF 34 ~ ICF 253 will have been standardized.
1 direction of the three directions stocks conversion tea of ??different flange size as a standard product.
It changes and the like of various dimensions, quickly can also be accommodated with respect to special order.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 152 |
ICF | 114 |
A | 152 |
B | 114 |
C | 101.6 |
C1 | 63.5 |
D | 97.4 |
D1 | 59.5 |
L1 | 105 |
L2 | 110 |
Attachment port of the vacuum gauge, has been used in the exhaust connection port and the like.
Up to ICF 34 ~ ICF 253 will have been standardized.
1 direction of the three directions stocks conversion tea of ??different flange size as a standard product.
It changes and the like of various dimensions, quickly can also be accommodated with respect to special order.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 203 |
ICF | 70 |
A | 203 |
B | 70 |
C | 153 |
C1 | 42.7 |
D | 147 |
D1 | 39.4 |
L1 | 135 |
L2 | 140 |
Attachment port of the vacuum gauge, has been used in the exhaust connection port and the like.
Up to ICF 34 ~ ICF 253 will have been standardized.
1 direction of the three directions stocks conversion tea of ??different flange size as a standard product.
It changes and the like of various dimensions, quickly can also be accommodated with respect to special order.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 203 |
ICF | 114 |
A | 203 |
B | 114 |
C | 153 |
C1 | 63.5 |
D | 147 |
D1 | 59.5 |
L1 | 160 |
L2 | 140 |
Attachment port of the vacuum gauge, has been used in the exhaust connection port and the like.
Up to ICF 34 ~ ICF 253 will have been standardized.
1 direction of the three directions stocks conversion tea of ??different flange size as a standard product.
It changes and the like of various dimensions, quickly can also be accommodated with respect to special order.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 203 |
ICF | 152 |
A | 203 |
B | 152 |
C | 153 |
C1 | 101.6 |
D | 147 |
D1 | 97.4 |
L1 | 135 |
L2 | 140 |
Attachment port of the vacuum gauge, has been used in the exhaust connection port and the like.
Up to ICF 34 ~ ICF 253 will have been standardized.
1 direction of the three directions stocks conversion tea of ??different flange size as a standard product.
It changes and the like of various dimensions, quickly can also be accommodated with respect to special order.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 253 |
ICF | 70 |
A | 253 |
B | 70 |
C | 203 |
C1 | 42.7 |
D | 197 |
D1 | 39.4 |
L1 | 160 |
L2 | 140 |
Attachment port of the vacuum gauge, has been used in the exhaust connection port and the like.
Up to ICF 34 ~ ICF 253 will have been standardized.
1 direction of the three directions stocks conversion tea of ??different flange size as a standard product.
It changes and the like of various dimensions, quickly can also be accommodated with respect to special order.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 253 |
ICF | 114 |
A | 253 |
B | 114 |
C | 203 |
C1 | 63.5 |
D | 197 |
D1 | 59.5 |
L1 | 180 |
L2 | 160 |
Attachment port of the vacuum gauge, has been used in the exhaust connection port and the like.
Up to ICF 34 ~ ICF 253 will have been standardized.
1 direction of the three directions stocks conversion tea of ??different flange size as a standard product.
It changes and the like of various dimensions, quickly can also be accommodated with respect to special order.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 253 |
ICF | 152 |
A | 253 |
B | 152 |
C | 203 |
C1 | 101.6 |
D | 197 |
D1 | 95.6 |
L1 | 190 |
L2 | 160 |
Attachment port of the vacuum gauge, has been used in the exhaust connection port and the like.
Up to ICF 34 ~ ICF 253 will have been standardized.
1 direction of the three directions stocks conversion tea of ??different flange size as a standard product.
It changes and the like of various dimensions, quickly can also be accommodated with respect to special order.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 253 |
ICF | 203 |
A | 253 |
B | 203 |
C | 203 |
C1 | 153 |
D | 197 |
D1 | 147 |
L1 | 200 |
L2 | 180 |
NW / KF, ICF, JIS VF / VG standards, tube end, various types of general-purpose joint end (Swagelok®, VCR®, tapered screw) stocks conversion adapter of various standards such as the type as a standard product.
Quickly it can also be accommodated with respect to special order items such as conversion and change of the tube size of the catalog with no standard.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 34 |
NW/KF | 16 |
A | 34 |
B | 30 |
C | 19 |
D | 16 |
C1 | 19 |
D1 | 16 |
L1 | 25 |
L2 | 38 |
NW / KF, ICF, JIS VF / VG standards, tube end, various types of general-purpose joint end (Swagelok®, VCR®, tapered screw) stocks conversion adapter of various standards such as the type as a standard product.
Quickly it can also be accommodated with respect to special order items such as conversion and change of the tube size of the catalog with no standard.
Flange material | SUS 304 |
---|---|
The inner surface processing | Buff 400 (equivalent to Ra 1.0 |
RoHS2 corresponding | ○ |
ICF | 34 |
NW/KF | 25 |
A | 34 |
B | 40 |
C | 19.1 |
D | 16.1 |
C1 | 19.1 |
D1 | 16.1 |
L1 | 25 |
L2 | 54 |