About 8,000 types of vacuum components in stock at all times.Business Hours: 9:00-18:00, excluding weekends and holidays

Product Category
  • Feedthrough Feedthrough
    Feedthrough
  • Isolator Isolator
    Isolator
  • Viewport Viewport
    Viewport
  • Vacuum Component Vacuum Component
    Vacuum Component
  • Vacuum Valve Vacuum Valve
    Vacuum Valve
  • Vented Screw Vented Screw
    Vented Screw
  • Others Others
    Others

Isolator Product List Isolator

Products 161Matter (101 ~120 )

Displayed results
Display switching
  • Product code :17871
    Model:F40ISL60KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 40
    Φ D1 41.7
    Φ D2 31.8
    Φ D3 34.8
    Φ D4 105
    L1 159.9
    L2 101.6
    T1 10
    T2 10
    Withstand voltage: DC 60 kV
  • Product code :16631
    Model:F50ISL12KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 50
    Φ D1 70
    Φ D2 56
    Φ D3 58.5
    Φ D4 120
    L1 72
    L2 20
    T1 10
    T2 10
    Withstand voltage: DC 12 kV
  • Product code :16632
    Model:F50ISL24KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 50
    Φ D1 70
    Φ D2 56
    Φ D3 58.5
    Φ D4 120
    L1 92
    L2 40
    T1 10
    T2 10
    Withstand voltage: DC 24 kV
  • Product code :17866
    Model:F50ISL30KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 50
    Φ D1 63.5
    Φ D2 50.8
    Φ D3 59.1
    Φ D4 120
    L1 85.3
    L2 50.8
    T1 10
    T2 10
    Withstand voltage: DC 30 kV
  • Product code :17872
    Model:F50ISL60KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 50
    Φ D1 41.7
    Φ D2 31.8
    Φ D3 34.8
    Φ D4 120
    L1 159.9
    L2 101.6
    T1 10
    T2 10
    Withstand voltage: DC 60 kV
  • Product code :16633
    Model:F65ISL12KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 65
    Φ D1 100
    Φ D2 75
    Φ D3 76.5
    Φ D4 145
    L1 85
    L2 20
    T1 10
    T2 10
    Withstand voltage: DC 12 kV
  • Product code :16634
    Model:F65ISL24KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 65
    Φ D1 100
    Φ D2 75
    Φ D3 76.5
    Φ D4 145
    L1 105
    L2 40
    T1 10
    T2 10
    Withstand voltage: DC 24 kV
  • Product code :16635
    Model:F80ISL12KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 80
    Φ D1 100
    Φ D2 75
    Φ D3 76.5
    Φ D4 145
    L1 85
    L2 20
    T1 10
    T2 10
    Withstand voltage: DC 12 kV
  • Product code :16636
    Model:F80ISL24KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 80
    Φ D1 100
    Φ D2 75
    Φ D3 76.5
    Φ D4 145
    L1 105
    L2 40
    T1 10
    T2 10
    Withstand voltage: DC 24 kV
  • Product code :16637
    Model:F100ISL12KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 100
    Φ D1 148
    Φ D2 122
    Φ D3 101.5
    Φ D4 185
    L1 95
    L2 20
    T1 10
    T2 10
    Withstand voltage: DC 12 kV
  • Product code :16638
    Model:F100ISL24KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 100
    Φ D1 148
    Φ D2 122
    Φ D3 101.5
    Φ D4 185
    L1 115
    L2 40
    T1 12
    T2 12
    Withstand voltage: DC 24 kV
  • Product code :16640
    Model:F125ISL24KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 125
    Φ D1 190
    Φ D2 135
    Φ D3 136
    Φ D4 210
    L1 120
    L2 40
    T1 12
    T2 12
    Withstand voltage: DC 24 kV
  • Product code :16639
    Model:F125ISL12KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 125
    Φ D1 190
    Φ D2 135
    Φ D3 136
    Φ D4 210
    L1 100
    L2 20
    T1 12
    T2 12
    Withstand voltage: DC 12 kV
  • Product code :16641
    Model:F150ISL12KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 150
    Φ D1 190
    Φ D2 135
    Φ D3 136
    Φ D4 210
    L1 100
    L2 20
    T1 12
    T2 12
    Withstand voltage: DC 12 kV
  • Product code :16642
    Model:F150ISL24KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 150
    Φ D1 190
    Φ D2 135
    Φ D3 136
    Φ D4 210
    L1 120
    L2 40
    T1 12
    T2 12
    Withstand voltage: DC 24 kV
  • Product code :16603
    Model:G10ISL6KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VG 10
    Φ D1 25
    Φ D2 14
    Φ D3 15.4
    Φ D4 70
    L1 52
    L2 10
    T1 8
    T2 8
    Withstand voltage: DC 6 kV
  • Product code :16604
    Model:G10ISL12KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VG 10
    Φ D1 25
    Φ D2 14
    Φ D3 15.4
    Φ D4 70
    L1 62
    L2 20
    T1 8
    T2 8
    Withstand voltage: DC 12 kV
  • Product code :16605
    Model:G20ISL12KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VG 20
    Φ D1 42
    Φ D2 27
    Φ D3 29
    Φ D4 80
    L1 54
    L2 20
    T1 8
    T2 8
    Withstand voltage: DC 12 kV
  • Product code :16606
    Model:G20ISL24KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VG 20
    Φ D1 42
    Φ D2 27
    Φ D3 29
    Φ D4 90
    L1 74
    L2 40
    T1 8
    T2 8
    Withstand voltage: DC 24 kV
  • Product code :17867
    Model:G20ISL30KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VG 20
    Φ D1 25.4
    Φ D2 19.1
    Φ D3 16
    Φ D4 80
    L1 91.4
    L2 50.8
    T1 8
    T2 8
    Withstand voltage: DC 30 kV
Shipping accepted on the day on orders until 17:00 Hours 9:00 to 18:00 except Saturdays, Sundays, and holidays
Contact Us
Please fill in the form below.
After confirming the content of your enquiry,
a representative will contact you.

To use this service, please login or register as a member.

Not a member yet?

Registering as a member gives you access to a number of useful features.

ぜひご登録ください!

※ Please note that it may take several days after applying for a member registration until the registration is complete. Please note that we reserve the right to refuse your application at our discretion.