About 8,000 types of vacuum components in stock at all times.Business Hours: 9:00-18:00, excluding weekends and holidays

Product Category
  • Feedthrough Feedthrough
    Feedthrough
  • Isolator Isolator
    Isolator
  • Viewport Viewport
    Viewport
  • Vacuum Component Vacuum Component
    Vacuum Component
  • Vacuum Valve Vacuum Valve
    Vacuum Valve
  • Vented Screw Vented Screw
    Vented Screw
  • Others Others
    Others

Isolator Product List Isolator

Products 160Matter (81 ~100 )

Displayed results
Display switching
  • Product code :10306
    Model:C114ISL12KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 114
    Φ D1 70
    Φ D2 56
    Φ D3 58.5
    Φ D4 60.5
    Φ D5 114
    Φ D6 80
    Φ D7 60
    L2 20
    L3 100.5 ~ 108.5
    T1 19
    T2 17.5
    Withstand voltage: DC 12 kV
  • Product code :10324
    Model:C114ISL24KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 114
    Φ D1 70
    Φ D2 56
    Φ D3 58.5
    Φ D4 60.5
    Φ D5 114
    Φ D6 80
    Φ D7 60
    L2 40
    L3 120.5 ~ 128.5
    T1 19
    T2 17.5
    Withstand voltage: DC 24 kV
  • Product code :10323
    Model:C152ISL12KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 152
    Φ D1 100
    Φ D2 75
    Φ D3 76.5
    Φ D4 79.5
    Φ D5 152
    Φ D6 100
    Φ D7 75
    L2 20
    L3 105.5 ~ 113.5
    T1 21
    T2 20
    Withstand voltage: DC 12 kV
  • Product code :12145
    Model:C152ISL24KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 152
    Φ D1 100
    Φ D2 75
    Φ D3 76.5
    Φ D4 79.5
    Φ D5 152
    Φ D6 100
    Φ D7 75
    L2 40
    L3 125.5 ~ 133.5
    T1 21
    T2 20
    Withstand voltage: DC 24 kV
  • Product code :12146
    Model:C203ISL12KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 203
    Φ D1 148
    Φ D2 122
    Φ D3 101.5
    Φ D4 104.5
    Φ D5 203
    Φ D6 162
    Φ D7 132
    L2 20
    L3 118 ~ 126
    T1 24
    T2 22
    Withstand voltage: DC 12 kV
  • Product code :12147
    Model:C203ISL24KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 203
    Φ D1 148
    Φ D2 122
    Φ D3 101.5
    Φ D4 104.5
    Φ D5 203
    Φ D6 162
    Φ D7 132
    L2 40
    L3 138 ~ 147
    T1 24
    T2 22
    Withstand voltage: DC 24 kV
  • Product code :12148
    Model:C253ISL12KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 253
    Φ D1 190
    Φ D2 135
    Φ D3 136
    Φ D4 140
    Φ D5 253
    Φ D6 185
    Φ D7 135
    L2 20
    L3 117 ~ 125
    T1 25
    T2 25
    Withstand voltage: DC 12 kV
  • Product code :12149
    Model:C253ISL24KVB

    ▼Insulated coupling ICF with bellows
    Bellows allows alignment adjustment between pipes and alleviation of stress on ceramics even in a narrow space
    Withstand voltage: 6kV, 12kV, 24kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253

    ▼The following types are standardized (List)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 253
    Φ D1 190
    Φ D2 135
    Φ D3 136
    Φ D4 140
    Φ D5 253
    Φ D6 185
    Φ D7 135
    L2 40
    L3 137 ~ 145
    T1 25
    T2 25
    Withstand voltage: DC 24 kV
  • Product code :16623
    Model:F10ISL6KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 10
    Φ D1 25
    Φ D2 14
    Φ D3 15.4
    Φ D4 70
    L1 52
    L2 10
    T1 8
    T2 8
    Withstand voltage: DC 6 kV
  • Product code :16624
    Model:F10ISL12KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 10
    Φ D1 25
    Φ D2 14
    Φ D3 15.4
    Φ D4 70
    L1 62
    L2 20
    T1 8
    T2 8
    Withstand voltage: DC 12 kV
  • Product code :16625
    Model:F20ISL12KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 20
    Φ D1 42
    Φ D2 27
    Φ D3 29
    Φ D4 80
    L1 54
    L2 20
    T1 8
    T2 8
    Withstand voltage: DC 12 kV
  • Product code :16626
    Model:F20ISL24KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 20
    Φ D1 42
    Φ D2 27
    Φ D3 29
    Φ D4 90
    L1 74
    L2 40
    T1 8
    T2 8
    Withstand voltage: DC 24 kV
  • Product code :17863
    Model:F20ISL30KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 20
    Φ D1 25.4
    Φ D2 19.1
    Φ D3 16
    Φ D4 80
    L1 91.4
    L2 50.8
    T1 8
    T2 8
    Withstand voltage: DC 30 kV
  • Product code :16627
    Model:F25ISL12KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 25
    Φ D1 42
    Φ D2 27
    Φ D3 29
    Φ D4 80
    L1 54
    L2 20
    T1 8
    T2 8
    Withstand voltage: DC 12 kV
  • Product code :16628
    Model:F25ISL24KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 25
    Φ D1 42
    Φ D2 27
    Φ D3 29
    Φ D4 90
    L1 74
    L2 40
    T1 8
    T2 8
    Withstand voltage: DC 24 kV
  • Product code :17864
    Model:F25ISL30KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 25
    Φ D1 25.4
    Φ D2 19.1
    Φ D3 16
    Φ D4 90
    L1 91.4
    L2 50.8
    T1 8
    T2 8
    Withstand voltage: DC 30 kV
  • Product code :16629
    Model:F40ISL12KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 40
    Φ D1 42
    Φ D2 27
    Φ D3 29
    Φ D4 80
    L1 54
    L2 20
    T1 8
    T2 8
    Withstand voltage: DC 12 kV
  • Product code :16630
    Model:F40ISL24KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 40
    Φ D1 42
    Φ D2 27
    Φ D3 29
    Φ D4 90
    L1 74
    L2 40
    T1 8
    T2 8
    Withstand voltage: DC 24 kV
  • Product code :17865
    Model:F40ISL30KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 40
    Φ D1 41.7
    Φ D2 31.8
    Φ D3 34.8
    Φ D4 105
    L1 96.5
    L2 50.8
    T1 10
    T2 10
    Withstand voltage: DC 30 kV
  • Product code :17871
    Model:F40ISL60KV

    Please select the most suitable fittings from the following standards and sizes: tube end, Swagelok, VCR female, VCR male, VCR male, NW/KF, JIS VF/VG.

    The standard withstand voltage for tube ends, Swageloks, VCR screws and VCR osses is 1.8 to 10kV.
    The standard withstand voltage for NW flanges is 12kV.
    The standard withstand voltage for ICF and JIS VF/VG flanges is 6 to 24kV. The standard is 6 to 24kV.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    VF 40
    Φ D1 41.7
    Φ D2 31.8
    Φ D3 34.8
    Φ D4 105
    L1 159.9
    L2 101.6
    T1 10
    T2 10
    Withstand voltage: DC 60 kV
Shipping accepted on the day on orders until 17:00 Hours 9:00 to 18:00 except Saturdays, Sundays, and holidays
Contact Us
Please fill in the form below.
After confirming the content of your enquiry,
a representative will contact you.

To use this service, please login or register as a member.

Not a member yet?

Registering as a member gives you access to a number of useful features.

ぜひご登録ください!

※ Please note that it may take several days after applying for a member registration until the registration is complete. Please note that we reserve the right to refuse your application at our discretion.