  • Product code :11940
    Model:FVCR1/2ISL10KV

    ▼VCR® Insulated joints
    Withstand voltage: 1.8kV, 10kV
    VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Joint standard VCR® F
    Tube / Fitting Size 1/2 inch
    L 101.4
    Withstand voltage: DC 10 kV
    sleeve Kovar ®
    87,100JPY (with tax 95,810JPY)
    Inquiry for this product
  • Product code :18877
    Model:MVCR1/16ISL2KV

    ▼VCR® Insulated joints
    Withstand voltage: 1.8kV, 10kV
    VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Joint standard VCR® M
    Tube / Fitting Size 1/16 inch
    L 65
    Withstand voltage: DC 2 kV
    sleeve 70-30 CuNi
    89,700JPY (with tax 98,670JPY)
    Inquiry for this product
  • Product code :18881
    Model:MVCR1/8ISL3KV

    ▼VCR® Insulated joints
    Withstand voltage: 1.8kV, 10kV
    VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Joint standard VCR® M
    Tube / Fitting Size 1/8 inch
    L 78
    Withstand voltage: DC 3 kV
    sleeve 70-30 CuNi
    67,100JPY (with tax 73,810JPY)
    Inquiry for this product
  • Product code :13589
    Model:MVCR1/4ISL1KV

    ▼VCR® Insulated joints
    Withstand voltage: 1.8kV, 10kV
    VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Joint standard VCR® M
    Tube / Fitting Size 1/4 inch
    L 86
    Withstand voltage: DC 1.8 kV
    sleeve Kovar ®
    35,500JPY (with tax 39,050JPY)
    Inquiry for this product
  • Product code :11899
    Model:MVCR1/4ISL10KV

    ▼VCR® Insulated joints
    Withstand voltage: 1.8kV, 10kV
    VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Joint standard VCR® M
    Tube / Fitting Size 1/4 inch
    L 108.4
    Withstand voltage: DC 10 kV
    sleeve SUS 304
    36,500JPY (with tax 40,150JPY)
    Inquiry for this product
  • Product code :11941
    Model:MVCR1/2ISL10KV

    ▼VCR® Insulated joints
    Withstand voltage: 1.8kV, 10kV
    VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
    ※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
    Integrated bellows type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    cap Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    Joint standard VCR® M
    Tube / Fitting Size 1/2 inch
    L 135.6
    Withstand voltage: DC 10 kV
    sleeve Kovar ®
    86,100JPY (with tax 94,710JPY)
    Inquiry for this product
  • Product code :11824
    Model:N16ISL12KV

    ▼ Insulation joint NW/KF
    Withstand voltage: 12kV, 30kV, 60kV
    Nominal flange diameter: 16, 25, 40, 50
    ※Ceramic part may be broken if tension is applied to the ceramic part.
    Bellows integrated type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 16
    A 30
    B 4.8
    Φ D1 25
    Φ D2 14
    Φ D3 15.4
    L 62
    L2 20
    Withstand voltage: DC 12 kV
    71,100JPY (with tax 78,210JPY)
    Inquiry for this product
  • Product code :16712
    Model:N16ISL30KV

    ▼ Insulation joint NW/KF
    Withstand voltage: 12kV, 30kV, 60kV
    Nominal flange diameter: 16, 25, 40, 50
    ※Ceramic part may be broken if tension is applied to the ceramic part.
    Bellows integrated type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 16
    A 30
    B 5
    Φ D1 25.4
    Φ D2 19.1
    Φ D3 16
    L 91.4
    L2 50.8
    Withstand voltage: DC 30 kV
    137,100JPY (with tax 150,810JPY)
    Inquiry for this product
  • Product code :10273
    Model:N25ISL12KV

    ▼ Insulation joint NW/KF
    Withstand voltage: 12kV, 30kV, 60kV
    Nominal flange diameter: 16, 25, 40, 50
    ※Ceramic part may be broken if tension is applied to the ceramic part.
    Bellows integrated type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 25
    A 40
    B 6
    Φ D1 25
    Φ D2 14
    Φ D3 15.4
    L 67
    L2 20
    Withstand voltage: DC 12 kV
    77,100JPY (with tax 84,810JPY)
    Inquiry for this product
  • Product code :16713
    Model:N25ISL30KV

    ▼ Insulation joint NW/KF
    Withstand voltage: 12kV, 30kV, 60kV
    Nominal flange diameter: 16, 25, 40, 50
    ※Ceramic part may be broken if tension is applied to the ceramic part.
    Bellows integrated type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 25
    A 40
    B 6
    Φ D1 25.4
    Φ D2 19.1
    Φ D3 16
    L 96.4
    L2 50.8
    Withstand voltage: DC 30 kV
    141,100JPY (with tax 155,210JPY)
    Inquiry for this product
  • Product code :10118
    Model:N40ISL12KV

    ▼ Insulation joint NW/KF
    Withstand voltage: 12kV, 30kV, 60kV
    Nominal flange diameter: 16, 25, 40, 50
    ※Ceramic part may be broken if tension is applied to the ceramic part.
    Bellows integrated type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 40
    A 55
    B 6
    Φ D1 42
    Φ D2 27
    Φ D3 29
    L 59
    L2 20
    Withstand voltage: DC 12 kV
    117,100JPY (with tax 128,810JPY)
    Inquiry for this product
  • Product code :40229
    Model:ZN40ISL30KV

    ▼ Insulation joint NW/KF
    Withstand voltage: 12kV, 30kV, 60kV
    Nominal flange diameter: 16, 25, 40, 50
    ※Ceramic part may be broken if tension is applied to the ceramic part.
    Bellows integrated type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 40
    A 55
    B 6
    Φ D1 25.4
    Φ D2 19
    Φ D3 19.1
    L 97
    L2 51
    Withstand voltage: DC 30 kV
    147,100JPY (with tax 161,810JPY)
    Inquiry for this product
  • Product code :16714
    Model:N40ISL30KV

    ▼ Insulation joint NW/KF
    Withstand voltage: 12kV, 30kV, 60kV
    Nominal flange diameter: 16, 25, 40, 50
    ※Ceramic part may be broken if tension is applied to the ceramic part.
    Bellows integrated type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 40
    A 55
    B 6
    Φ D1 41.4
    Φ D2 31.8
    Φ D3 34.8
    L 102
    L2 51
    Withstand voltage: DC 30 kV
    147,100JPY (with tax 161,810JPY)
    Inquiry for this product
  • Product code :16722
    Model:N40ISL60KV

    ▼ Insulation joint NW/KF
    Withstand voltage: 12kV, 30kV, 60kV
    Nominal flange diameter: 16, 25, 40, 50
    ※Ceramic part may be broken if tension is applied to the ceramic part.
    Bellows integrated type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 40
    A 55
    B 5
    Φ D1 41.4
    Φ D2 31.8
    Φ D3 34.8
    L 156.7
    L2 101.6
    Withstand voltage: DC 60 kV
    157,100JPY (with tax 172,810JPY)
    Inquiry for this product
  • Product code :11839
    Model:N50ISL12KV

    ▼ Insulation joint NW/KF
    Withstand voltage: 12kV, 30kV, 60kV
    Nominal flange diameter: 16, 25, 40, 50
    ※Ceramic part may be broken if tension is applied to the ceramic part.
    Bellows integrated type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 50
    A 75
    B 6
    Φ D1 42
    Φ D2 27
    Φ D3 29
    L 59
    L2 20
    Withstand voltage: DC 12 kV
    141,100JPY (with tax 155,210JPY)
    Inquiry for this product
  • Product code :16715
    Model:N50ISL30KV

    ▼ Insulation joint NW/KF
    Withstand voltage: 12kV, 30kV, 60kV
    Nominal flange diameter: 16, 25, 40, 50
    ※Ceramic part may be broken if tension is applied to the ceramic part.
    Bellows integrated type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 50
    A 75
    B 5
    Φ D1 41.4
    Φ D2 31.8
    Φ D3 34.8
    L 102.4
    L2 50.8
    Withstand voltage: DC 30 kV
    151,100JPY (with tax 166,210JPY)
    Inquiry for this product
  • Product code :16723
    Model:N50ISL60KV

    ▼ Insulation joint NW/KF
    Withstand voltage: 12kV, 30kV, 60kV
    Nominal flange diameter: 16, 25, 40, 50
    ※Ceramic part may be broken if tension is applied to the ceramic part.
    Bellows integrated type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    NW/KF 50
    A 75
    B 5
    Φ D1 41.4
    Φ D2 31.8
    Φ D3 34.8
    L 156.7
    L2 101.6
    Withstand voltage: DC 60 kV
    171,100JPY (with tax 188,210JPY)
    Inquiry for this product
  • Product code :10062
    Model:C34ISL6KV

    ▼Insulation joint ICF
    Withstanding voltage: 6kV, 12kV, 24kV, 30kV, 40kV, 60kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253
    ※The use of bellows is recommended because of the risk of cracking when tension is applied to the ceramic part.
    Bellows integrated type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 34
    Φ D1 25
    Φ D2 14
    Φ D3 15.4
    Φ D4 34
    L1 60
    L2 10
    T1 7.5
    T2 7.5
    Withstand voltage: DC 6 kV
    110,100JPY (with tax 121,110JPY)
    Inquiry for this product
  • Product code :10063
    Model:C34ISL12KV

    ▼Insulation joint ICF
    Withstanding voltage: 6kV, 12kV, 24kV, 30kV, 40kV, 60kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253
    ※The use of bellows is recommended because of the risk of cracking when tension is applied to the ceramic part.
    Bellows integrated type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 34
    Φ D1 25
    Φ D2 14
    Φ D3 15.4
    Φ D4 34
    L1 70
    L2 20
    T1 7.5
    T2 7.5
    Withstand voltage: DC 12 kV
    137,100JPY (with tax 150,810JPY)
    Inquiry for this product
  • Product code :16716
    Model:C34ISL30KV

    ▼Insulation joint ICF
    Withstanding voltage: 6kV, 12kV, 24kV, 30kV, 40kV, 60kV
    Nominal flange diameter: 34, 70, 114, 152, 203, 253
    ※The use of bellows is recommended because of the risk of cracking when tension is applied to the ceramic part.
    Bellows integrated type is also available for tight spaces (ICF only).

    ▼The following types are standardized (list)
    Tubing: Tube ends, Swagelok® fittings, VCR® fittings
    Flanges: ICF, NW/KF, JIS-VF, JIS-VG
    Bellows integrated type (ICF)

    ▼Custom-made products are also available.
    We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.

    For precision cleaning requests, please click here.

    type Insulation flange
    sleeve Kovar ®
    Insulator Alumina ceramic
    Maximum temperature 300℃
    The lowest temperature -196℃
    Leak rate <1.3x10<sup>-10</sup>Pa・㎥/sec
    RoHS2 corresponding
    ICF 34
    Φ D1 25.4
    Φ D2 19.1
    Φ D3 16
    Φ D4 34
    L1 91.4
    L2 50.8
    T1 7.5
    T2 7.5
    Withstand voltage: DC 30 kV
    147,100JPY (with tax 161,810JPY)
    Inquiry for this product
Shipping accepted on the day on orders until 17:00 Hours 9:00 to 18:00 except Saturdays, Sundays, and holidays
Contact Us
Please fill in the form below.
After confirming the content of your enquiry,
a representative will contact you.

To use this service, please login or register as a member.

Not a member yet?

Registering as a member gives you access to a number of useful features.

ぜひご登録ください!

※ Please note that it may take several days after applying for a member registration until the registration is complete. Please note that we reserve the right to refuse your application at our discretion.