About 8,000 types of vacuum components in stock at all times.Business Hours: 9:00-18:00, excluding weekends and holidays
▼VCR® Insulated joints
Withstand voltage: 1.8kV, 10kV
VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
※Integrated bellows type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
cap | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
Joint standard | VCR® F |
Tube / Fitting Size | 1/2 inch |
L | 101.4 |
Withstand voltage: DC | 10 kV |
sleeve | Kovar ® |
▼VCR® Insulated joints
Withstand voltage: 1.8kV, 10kV
VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
※Integrated bellows type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
cap | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
Joint standard | VCR® M |
Tube / Fitting Size | 1/16 inch |
L | 65 |
Withstand voltage: DC | 2 kV |
sleeve | 70-30 CuNi |
▼VCR® Insulated joints
Withstand voltage: 1.8kV, 10kV
VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
※Integrated bellows type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
cap | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
Joint standard | VCR® M |
Tube / Fitting Size | 1/8 inch |
L | 78 |
Withstand voltage: DC | 3 kV |
sleeve | 70-30 CuNi |
▼VCR® Insulated joints
Withstand voltage: 1.8kV, 10kV
VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
※Integrated bellows type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
cap | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
Joint standard | VCR® M |
Tube / Fitting Size | 1/4 inch |
L | 86 |
Withstand voltage: DC | 1.8 kV |
sleeve | Kovar ® |
▼VCR® Insulated joints
Withstand voltage: 1.8kV, 10kV
VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
※Integrated bellows type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
cap | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
Joint standard | VCR® M |
Tube / Fitting Size | 1/4 inch |
L | 108.4 |
Withstand voltage: DC | 10 kV |
sleeve | SUS 304 |
▼VCR® Insulated joints
Withstand voltage: 1.8kV, 10kV
VCR® joints are available in combinations of double-sided male, double-sided female, and female male.
※Because of the risk of cracking when tension is applied to the ceramic part, we recommend the use of bellows in combination with the ceramic part.
※Integrated bellows type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
cap | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
Joint standard | VCR® M |
Tube / Fitting Size | 1/2 inch |
L | 135.6 |
Withstand voltage: DC | 10 kV |
sleeve | Kovar ® |
▼ Insulation joint NW/KF
Withstand voltage: 12kV, 30kV, 60kV
Nominal flange diameter: 16, 25, 40, 50
※Ceramic part may be broken if tension is applied to the ceramic part.
※Bellows integrated type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
NW/KF | 16 |
A | 30 |
B | 4.8 |
Φ D1 | 25 |
Φ D2 | 14 |
Φ D3 | 15.4 |
L | 62 |
L2 | 20 |
Withstand voltage: DC | 12 kV |
▼ Insulation joint NW/KF
Withstand voltage: 12kV, 30kV, 60kV
Nominal flange diameter: 16, 25, 40, 50
※Ceramic part may be broken if tension is applied to the ceramic part.
※Bellows integrated type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
NW/KF | 16 |
A | 30 |
B | 5 |
Φ D1 | 25.4 |
Φ D2 | 19.1 |
Φ D3 | 16 |
L | 91.4 |
L2 | 50.8 |
Withstand voltage: DC | 30 kV |
▼ Insulation joint NW/KF
Withstand voltage: 12kV, 30kV, 60kV
Nominal flange diameter: 16, 25, 40, 50
※Ceramic part may be broken if tension is applied to the ceramic part.
※Bellows integrated type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
NW/KF | 25 |
A | 40 |
B | 6 |
Φ D1 | 25 |
Φ D2 | 14 |
Φ D3 | 15.4 |
L | 67 |
L2 | 20 |
Withstand voltage: DC | 12 kV |
▼ Insulation joint NW/KF
Withstand voltage: 12kV, 30kV, 60kV
Nominal flange diameter: 16, 25, 40, 50
※Ceramic part may be broken if tension is applied to the ceramic part.
※Bellows integrated type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
NW/KF | 25 |
A | 40 |
B | 6 |
Φ D1 | 25.4 |
Φ D2 | 19.1 |
Φ D3 | 16 |
L | 96.4 |
L2 | 50.8 |
Withstand voltage: DC | 30 kV |
▼ Insulation joint NW/KF
Withstand voltage: 12kV, 30kV, 60kV
Nominal flange diameter: 16, 25, 40, 50
※Ceramic part may be broken if tension is applied to the ceramic part.
※Bellows integrated type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
NW/KF | 40 |
A | 55 |
B | 6 |
Φ D1 | 42 |
Φ D2 | 27 |
Φ D3 | 29 |
L | 59 |
L2 | 20 |
Withstand voltage: DC | 12 kV |
▼ Insulation joint NW/KF
Withstand voltage: 12kV, 30kV, 60kV
Nominal flange diameter: 16, 25, 40, 50
※Ceramic part may be broken if tension is applied to the ceramic part.
※Bellows integrated type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
NW/KF | 40 |
A | 55 |
B | 6 |
Φ D1 | 41.4 |
Φ D2 | 31.8 |
Φ D3 | 34.8 |
L | 102 |
L2 | 51 |
Withstand voltage: DC | 30 kV |
▼ Insulation joint NW/KF
Withstand voltage: 12kV, 30kV, 60kV
Nominal flange diameter: 16, 25, 40, 50
※Ceramic part may be broken if tension is applied to the ceramic part.
※Bellows integrated type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
NW/KF | 40 |
A | 55 |
B | 5 |
Φ D1 | 41.4 |
Φ D2 | 31.8 |
Φ D3 | 34.8 |
L | 156.7 |
L2 | 101.6 |
Withstand voltage: DC | 60 kV |
▼ Insulation joint NW/KF
Withstand voltage: 12kV, 30kV, 60kV
Nominal flange diameter: 16, 25, 40, 50
※Ceramic part may be broken if tension is applied to the ceramic part.
※Bellows integrated type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
NW/KF | 50 |
A | 75 |
B | 6 |
Φ D1 | 42 |
Φ D2 | 27 |
Φ D3 | 29 |
L | 59 |
L2 | 20 |
Withstand voltage: DC | 12 kV |
▼ Insulation joint NW/KF
Withstand voltage: 12kV, 30kV, 60kV
Nominal flange diameter: 16, 25, 40, 50
※Ceramic part may be broken if tension is applied to the ceramic part.
※Bellows integrated type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
NW/KF | 50 |
A | 75 |
B | 5 |
Φ D1 | 41.4 |
Φ D2 | 31.8 |
Φ D3 | 34.8 |
L | 102.4 |
L2 | 50.8 |
Withstand voltage: DC | 30 kV |
▼ Insulation joint NW/KF
Withstand voltage: 12kV, 30kV, 60kV
Nominal flange diameter: 16, 25, 40, 50
※Ceramic part may be broken if tension is applied to the ceramic part.
※Bellows integrated type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
NW/KF | 50 |
A | 75 |
B | 5 |
Φ D1 | 41.4 |
Φ D2 | 31.8 |
Φ D3 | 34.8 |
L | 156.7 |
L2 | 101.6 |
Withstand voltage: DC | 60 kV |
▼Insulation joint ICF
Withstanding voltage: 6kV, 12kV, 24kV, 30kV, 40kV, 60kV
Nominal flange diameter: 34, 70, 114, 152, 203, 253
※The use of bellows is recommended because of the risk of cracking when tension is applied to the ceramic part.
※Bellows integrated type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
ICF | 34 |
Φ D1 | 25 |
Φ D2 | 14 |
Φ D3 | 15.4 |
Φ D4 | 34 |
L1 | 60 |
L2 | 10 |
T1 | 7.5 |
T2 | 7.5 |
Withstand voltage: DC | 6 kV |
▼Insulation joint ICF
Withstanding voltage: 6kV, 12kV, 24kV, 30kV, 40kV, 60kV
Nominal flange diameter: 34, 70, 114, 152, 203, 253
※The use of bellows is recommended because of the risk of cracking when tension is applied to the ceramic part.
※Bellows integrated type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
ICF | 34 |
Φ D1 | 25 |
Φ D2 | 14 |
Φ D3 | 15.4 |
Φ D4 | 34 |
L1 | 70 |
L2 | 20 |
T1 | 7.5 |
T2 | 7.5 |
Withstand voltage: DC | 12 kV |
▼Insulation joint ICF
Withstanding voltage: 6kV, 12kV, 24kV, 30kV, 40kV, 60kV
Nominal flange diameter: 34, 70, 114, 152, 203, 253
※The use of bellows is recommended because of the risk of cracking when tension is applied to the ceramic part.
※Bellows integrated type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
ICF | 34 |
Φ D1 | 25.4 |
Φ D2 | 19.1 |
Φ D3 | 16 |
Φ D4 | 34 |
L1 | 91.4 |
L2 | 50.8 |
T1 | 7.5 |
T2 | 7.5 |
Withstand voltage: DC | 30 kV |
▼Insulation joint ICF
Withstanding voltage: 6kV, 12kV, 24kV, 30kV, 40kV, 60kV
Nominal flange diameter: 34, 70, 114, 152, 203, 253
※The use of bellows is recommended because of the risk of cracking when tension is applied to the ceramic part.
※Bellows integrated type is also available for tight spaces (ICF only).
▼The following types are standardized (list)
Tubing: Tube ends, Swagelok® fittings, VCR® fittings
Flanges: ICF, NW/KF, JIS-VF, JIS-VG
Bellows integrated type (ICF)
▼Custom-made products are also available.
We can also change lengths, fittings, and flange sizes. Please contact us by clicking the "Inquiry" button on the right side of the page.
For precision cleaning requests, please click here.
type | Insulation flange |
---|---|
sleeve | Kovar ® |
Insulator | Alumina ceramic |
Maximum temperature | 300℃ |
The lowest temperature | -196℃ |
Leak rate | <1.3x10<sup>-10</sup>Pa・㎥/sec |
RoHS2 corresponding | ○ |
ICF | 70 |
Φ D1 | 42 |
Φ D2 | 27 |
Φ D3 | 29 |
Φ D4 | 70 |
L1 | 62 |
L2 | 20 |
T1 | 12.7 |
T2 | 12.7 |
Withstand voltage: DC | 12 kV |